Press the
key. The
EM-4058
will automatically apply Wenner’s
equation (below) based on collected data.
=
4 Ra
a + 4 p
2
2
a
1 +
-
a + p
2
2
Legend:
= soil resistivity value; will be shown on the display
a
= distance (in meters) between rods; specified by the operator
p
= insertion depth (in meters) of the rods – the
EM-4058
uses
0,25 m
R
= resistance value used by the equipment to calculate
ρ
The display will then show the soil resistivity value, as in the example
below:
To properly evaluate soil resistivity, measurements must cover the whole
area to be influenced by the grounding system. For an area of up to
10,000 m², it is recommended to perform measurements in at least five
points, arranged as shown in the next image. Two sets of measurements
should be needed for the central point.