Introduction of Home Screen:
State of Measurement
;
Entry Menu
.
State of Menu
;
Entry state of changing parameter
.
State of changing parameter
;
save chance and back to menu state
ESC:
SET:
UP:
DOWN:
State of Measuremen
t;
Back to home screen
.
State of Menu
;
Exit menu
.
State of changing parameter
;
Not save chance and back to menu state
.
State of Measurement
;
To navigate from a main measurement values to another
.
State of Men
u;
To navigate from menu parameters to another
.
State of changing parameter
;
Increase value of parameter
State of Measurement
;
To navigate from a deep measurement values to another
(min,max,avg, dmd)
.
State of Menu
;
To navigate from menu parameters to another
.
State of changing parameter
;
Decrease value of parameter
7- Definition of Buttons:
1 - It shows phase number belong to measurement values
2 - Showing values are minimum of measurement values
3 - Showing values are maximum of measurement values
4 - Showing values are average of measurement values
5 - Showing values are demand of measurement values
6 - It shows Serial Communications
7 - It shows that type of measurement values
8- It shows phase sequence. “L123” means that phase sequence is correct.”L132” means that phase
sequence is incorrect.
-3-
Read the warnings before the device is energized. Make sure that the device is connected according to
the connection diagram. When the device energized for the first time, the Home Screen is displayed. Enter
the current transformer ratio and the voltage transformer ratios, if installed, on the settings menu at first.
8 -
Start-up of the Device
:
Home Screen:
It shows voltage and current values together. If protection type is L-N, it shows
phase-neutral voltage else, if protection type is L-L it shows phase-phase voltage. If you use voltage
transformer, it is not showed.
The figure-
3
is displayed when you press the Down button.
Figure-3:
It shows the phase-neutral voltage values. The figure-4 is displayed when you press the
Down button.
Figure-4:
It shows the phase-neutral minimum voltage values. The figure-5 is displayed when you press
the Down button.
Figure-5:
It shows the phase-neutral maximum voltage values. The figure-6 is displayed when you press
the Down button.
Figure-6:
It shows the phase-neutral mean voltage values. The figure-7 is displayed when you press the
Down button.
Figure-7:
It shows the phase- phase voltage values. The figure-8 is displayed when you press the Down
button.
Figure-8:
It shows the phase- phase minimum voltage values. The figure-9 is displayed when you press
the Down button.
Figure-9:
It shows the phase- phase maximum voltage values. The figure-10 is displayed when you press
the Down button.
Figure-10:
It shows the phase- phase mean voltage values. The figure-11 is displayed when you press the
Down button.
9 -
Display Information
:
Figure-3
L1
L2
L3
V
V
V
V
Figure-7
L12
L23
L31
V
V
V
V
Figure-4
L1
L2
L3
V
V
V
V
Figure-8
L12
L23
L31
V
V
V
V
Figure-5
L1
L2
L3
V
V
V
V
Figure-9
L12
L23
L31
V
V
V
V
Figure-6
L1
L2
L3
V
V
V
V
Figure-10
L12
L23
L31
V
V
V
V
-4-
L1
L2
L3
V
A
A
A
I
Home Screen
L1
L2
L3
I
A
A
A
L1
L2
L3
I
A
A
A
L1
L2
L3
I
A
A
A
L1
L2
L3
I
A
A
A
L1
L2
L3
I
A
A
A
Figure-11
Figure-12
Figure-13
Figure-15
Figure-14
Figure-11:
It shows the current values of each phase. The figure-12 is displayed when you press the
Down button.
Figure-12:
It shows the minimum current values of each phase. The figure-13 is displayed when you
press the Down button.
Figure-13:
It shows the maximum current values of each phase. The figure-14 is displayed when you
press the Down button.
Figure-14:
It shows the mean current values of each phase. The figure-15 is displayed when you press
the Down button.
Figure-15:
It shows the current demand current values of each phase. The figure-16 is displayed when
you press the Down button.
1
Min Max Ave Dmd
3
2
4 5
6
7
S
F I
8