Programming Parameter:
3
+
SET
Press for 2 sec.
Upper Display
Enter 162 to pass to
parameters prog. mode.
SET
Inpt
Sensor Type (1)
SET
Back
P
re
ss
“
B
ac
k”
to
r
et
ur
n
to
th
e
to
p
of
p
ar
am
et
er
s
pr
og
ra
m
m
in
g
bl
oc
k.
CodE
“tunE”
flashes
Enter 262 to
start
“auto-tune”
Upper Display
h-C
Select
Function (2)
SET
H.Hys/C.Hys
0..50 /
0.0 .. 5.0 (3)
o
C
SET
A.hys
1..50 /
0.0 .. 5.0 (3)
o
C
SET
Pb.C
10 .. 130
o
C
SET
Ct
4..200 sec
SET
ti
0..30.0 min
SET
td
0..10.0 min
SET
UP.L
Lo.L ..
Upper Scale (
o
C)
SET
oFFS
-100 .. +100 /
-10.0 .. +10.0 (
o
C) (3)
SET
SET
AL.tY
Abs, rel, bnd, bn.i
-Abs, -rel, -bnd, -bn.i
SET
r.ALr/
b.ALr
-100.. +100 /
-10.0 .. +10.0 (
o
C) (3)
SET
C.dLY
0..30 sec
SET
P.Err
%0..100
SET
End Prog.
HeAt:
Heating Function
Cool:
Cooling Function
Heat/Cool Hysteresis
o
( C):
PID is active if set to O
o
(for H.Hys)( C)
Alarm Hysteresis
o
( C)
o
Proportional Band in ( C)
Control Period (sec.)
Integral Time:
In minutes. If set to 0,
P, PD is active (integral OFF).
Derivative Time:
In minutes. If set to 0,
P, PI is active (derivative OFF).
C.Hys/
H.Hys
not 0
Upper limit value for Lo.L,
H.SET and A.SET. Upper Scale value
differs according to the selected
sensor type.
Offset Value; Offset is directly added
to the measured value. This feature shall
be used for user calibration. Normally set to 0.
LO.L
Lower Scale ..
UP.L (
o
C)
Lower limit value for UP.L,
H.SET and A.SET. Lower Scale value
differs according to the selected
sensor type.
Alarm Type:
Abs: Absolute, -Abs: Absolute, invert out
rel: Relative, -rel: Relative,
bnd: Band, -bnd: Band,
bn.i: Band inhibit, -bn.i: Band,
invert out
invert out
invert out
Relative or band Alarm Value.
Displayed if AL.tY is other then
Abs or -Abs.
Active only in cooling mode.
Minimum delay before OUT becomes ON
after it becomes OFF.
Determines the duty cycle of OUT output
when “Fail” message is displayed. If 0, OUT is always OFF.
If 100, OUT is always ON, when device “fails”. Period is Ct.
(1) When sensor type is changed, Up.L, Lo.L, H.Set or A.Set may be set to a new value automatically, if any of
then violates measuring scale of the selected sensor.
(2) ON-OFF control is only option for Cooling function.
(3) If sensor type is selected as Pt.0.
AL.tY=
Abs, -Abs
h-C=
heat
SET
J: J Type T\C, K: K Type T\C
T: T Type T\C, S: S Type T\C
R: R Type T\C, Pt: Pt100
Pt.0: 0.1 resolution Pt100
o
C
Factory Set
Values:
H.Set: 100
o
C
o
A.Set: 400 C
Inpt: J
H-C: Heat
o
H.hys: 3 C
o
A.hys: 3 C
o
Pb.C: 30 C
Ct: 4 sec.
ti: 5.0 min.
td: 1.0 min.
o
UP.L: 400 C
o
Lo.L: 0 C
o
oFFS: 0 C
AL.tY: rel
o
r.ALr: 3 C
C.dLy: 15 sec.
P.Err: 0
Auto Tune:
Before starting “Auto-tune”, adjust H.SET.
“Auto tune” does not start in“cooling” mode.
Process value may exceed H.Set during
auto-tune.
After auto-tuning, control form automatically
switches to PID mode.
Auto-tuning is stopped (interrupted) ant time
by pressing any key. In this case, the
parameters before auto-tuning is valid.
Auto-tuning may not always determine the
best values for your process.
CodE
Enter 162