LUBRICATION SCHEDULE FOR SEW-EURODRIVE GEAR UNITS
Gear
Reducer
Type
1)
Lubrication
Type
Ambient air
temperature
range °F
ISO
Viscosity
Grade
Mobil
Oil Co.
CHEVRON
Oil Co.
Shell
Oil Co.
Texaco
Oil Co.
BP
Oil Co.
Kluber
Oil Co.
R
F
K
Oil
+14
to
+104
VG220
Mobilgear
630
Chevron
Non-Leaded
Gear
Compound
220
Shell Omala
Oil 220
Meropa 220
BP Energol
GP-XP 220
Kluberoil
GEM 1-220
-4
to
+77
VG150
VG100
Mobilgear
629
Chevron
Non-Leaded
Gear
Compound
150
Shell Omala
Oil 100
Meropa 150
BP Energol
GP-XP 100
Kluberoil
GEM 1-150
S
Oil
+32
to
+104
VG680
Mobilgear
636
Chevron
Non-Leaded
Gear
Compound
680
Shell Omala
Oil 680
Meropa 680
BP Energol
GP-XP 680
Kluberoil
GEM 1-680
+5
to
+77
VG220
Mobilgear
630
Chevron
Non-Leaded
Gear
Compound
220
Shell Omala
Oil 220
Meropa 220
BP Energol
GP-XP 220
Kluberoil
GEM 1-220
General
Synth. Oil
+176
to
-40
Consult Factory For Use of Synthetic Oils
Synth.
Grease
+176
to
-40
Consult Factory For Use of Grease Filled Reducers
Ball & Roller
Bearings
Grease
Used for normal application
Temp. Range: -22°F to 140°F
Mobilux
EP2
Chevron
Dura-Lith
EP2
Shell
Alvania
Grease R3
Multifak
EP2
BP
Energrease
LS3
CENTOPLEX
2EP
1)
Applies to all reducers with or without motor and input shaft.
LUBRICANTS
2
Oil levels and oil quality should be checked at frequent intervals,
depending on usage. Oil changes are required at intervals of
10,000 operating hours or every two years, whichever comes first.
If a synthetic oil lubricant is used, then this period can be extended
to 20,000 operating hours or every four years, whichever comes
first. In applications where hostile operating conditions exist,
such as high humidity, corrosive environment, or large tempera-
ture changes, the lubricant should be changed at more frequent in-
tervals.
The gear units W20 and W30 are supplied with a synthetic oil
which is good for the life of the reducer, independent of the mount-
ing position.
Grease packed bearings should be cleaned and regreased ev-
ery 10,000 hours or 20,000 hours for synthetic grease. Input
(high speed) bearings should not be overgreased. They
should be filled with grease not to exceed 1/3 of the bearing’s
free volume. For output bearings and bearings with replace-
able grease shields, fill to 2/3 of their free volume.
ATTENTION
When the recommended lubricant is not avilable, it is permis-
sible to use a lubricant having equivalent characteristics but
we do not recommend that lubricants of different brands be
mixed. Under no circumstances should synthetic lubricants
be mixed with one another or with one having a mineral base.
Содержание LM1014
Страница 5: ...5...
Страница 6: ...6...
Страница 7: ...7...
Страница 11: ...11 LM Control Box Overlay...
Страница 20: ...20...
Страница 21: ...21 LM Machine PARTS View...
Страница 24: ...24 LM 2x Back gauge Crank Assembly...
Страница 26: ...26 LM 2x Back gauge Pointer Assembly...
Страница 28: ...28 LM 2x Back gauge Drive Assembly...
Страница 29: ...29 LM 2x Back gauge Arm Assembly...
Страница 31: ...31 LM Four Foot Squaring Arm...