5. Install the hydraulic pump (1) onto the pump

mounting bracket. (Fig. 1)

6. Connect the hoses from the hopper lift

cylinder to the hydraulic pump (1). (Fig. 1)

7. Connect the wire harness to the hydraulic

pump (1).

8. Fill the hydraulic pump (1) with hydraulic fluid

until the hydraulic fluid is at the correct level.

(Fig. 1)

9. Reconnect the battery cable to the machine.

10. Turn on the machine, raise and lower the

hopper several times, lower the hopper, and

turn off the machine. Check the hydraulic

pump / hydraulic hose connections for leaks.

11. Check the hydraulic level in the hydraulic

pump (1). Add hydraulic fluid as necessary

until the hydraulic fluid is at the correct level.

The hopper must be completely lowered

before checking hydraulic level / adding

hydraulic fluid.

1

FRONT

Hopper lift cylinder

Set M10 hex screws

(Qty. 2) / flat washers

(Qty. 2) aside

Pump mounting

bracket

Check hydraulic fluid level in hydraulic pump (1).

Hopper must be completely lowered before checking

hydraulic level / adding hydraulic fluid.

FIG. 1