background image

IB 340753 (01- 2007)

3

11. Remove the center arm plates (D) and the

scrub head lift spring (E) from the scrub head.

Set center arm plates, scrub head lift spring,

and all hardware (F) aside. Refer to Fig. 3.

12. Remove the lift bracket (G) from the scrub

head. Set the lift bracket and hardware (H)

aside. Refer to Fig. 3.

D

E

D

F

F

F

F

F

H

G

F

FIG. 3

Содержание 9000136

Страница 1: ...cycle PREPARATION 1 Empty the solution and recovery tanks Refer to the Operators Manual for instructions 2 Park the machine on a clean level surface and if necessary raise the scrub head Turn off the machine 3 Remove the brushes from the machine 4 Turn on the machine and lower the scrub head and squeegees 5 Turn off the machine and remove the key FOR SAFETY Before leaving or servicing machine stop...

Страница 2: ... Disconnect wires and hose from solenoid valve FIG 1 9 Remove the hardware A holding the scrub head to the machine and slide the scrub head from under the machine Set the hardware aside Refer to Fig 2 10 Remove the lift arms B from the scrub head Set the lift arms and hardware C aside Refer to Fig 2 Remove hardware A not shown from this side of machine also B A A A A A C C C C Actuator FIG 2 ...

Страница 3: ...scrub head lift spring E from the scrub head Set center arm plates scrub head lift spring and all hardware F aside Refer to Fig 3 12 Remove the lift bracket G from the scrub head Set the lift bracket and hardware H aside Refer to Fig 3 D E D F F F F F H G F FIG 3 ...

Страница 4: ...3 4 Position the scrub head under the machine and use the saved hardware A to install the scrub head onto the machine Refer to Fig 2 5 Connect all loose hoses wires and cables disconnected from the removed scrub head to the new scrub head Refer to Fig 1 6 Install the brushes onto the scrub head 7 Remove the jack stands from under the machine and lower the machine to the floor 8 Reconnect the batte...

Отзывы: