MAINTENANCE
6100E 330250 (9--02)
44
5.If the level is low, add just enough distilled
water to cover the battery plates. DO NOT
OVERFILL. The batteries can overflow
during charging due to expansion.
NOTE: Make sure the battery caps are in place
while charging.
FOR SAFETY: When maintaining or
servicing machine, avoid contact with
battery acid.
6. Unplug the battery connector from the
machine connector.
7. Plug the connector from the batteries into
the battery charger connector.
WARNING: Batteries emit hydrogen gas.
Explosion or fire can result. Keep
sparks and open flame away. Keep
covers open when charging.
NOTE: Plug the charger connector into connector
that runs to the batteries. Do not plug charger into
mounted connector. Damage may occur to the
machine.
NOTE: If the red “ABNORMAL CYCLE” lamp
lights when the batteries are plugged into the
TENNANT charger, this indicates that something
is wrong with the battery. The charger can not
charge the battery when this happens.