MAINTENANCE
39
6080 330000 (3--99)
CLEANING THE PANEL FILTER
The panel filter filters the air pulled up from the
hopper. The panel filter is equipped with a shaker
to remove the accumulated dust particles.
Remove and thoroughly clean the panel filter after
every 100 hours of use.
To remove the panel filter, unlatch and lower the
filter compartment door.
Unlatch the panel filter retainer and remove the
filter.
To clean the panel filter, use one of the following
methods:
D
TAPPING -- Tap the filter gently on a flat
surface with the dirty side down. Do not
damage the edges of the filter element, or
the filter will not seat properly in the filter
compartment.
D
AIR -- Blow air through the filter from the
opposite the side of the fingertabs. Always
wear eye protection when using compressed
air.
FOR SAFETY: When servicing machine,
wear eye and ear protection if using
pressurized air or water.
D
WATER -- Soak the filter in a water and mild
detergent solution. Rinse the filter until it is
clean. Air dry the filter; do not use
compressed air.
NOTE: Be sure the dust filter is completely dry
before reinstalling it in the machine.
Содержание 6080
Страница 1: ...6080 330000 Rev 04 é B ê Operator Manual ...
Страница 4: ...CONTENTS 6080 330000 9 97 2 ...