MAINTENANCE
57
5680 331176 (3--08)
SOLUTION SYSTEM
RECOVERY TANK
The recovery tank stores recovered solution. The
recovery tank should be drained and cleaned
daily. The outside of the tank can be cleaned with
vinyl cleaner.
NOTE: DO NOT use steam to clean the tank.
Excessive heat can damage the tanks and
components.
Rinse and wipe off the sensors daily on machines
with float sensors installed inside the recovery
tank.
A vacuum fan filter is located in the recovery tank.
Remove and clean this filter daily. Clean by
shaking dust or rinsing pleats with low pressure
water.
NOTE: Be sure the vacuum filter is dry before
reinstalling it in the machine.