OPERATION
355D MM301 (3--97)
26
CIRCUIT BREAKERS
The circuit breakers are resetable electrical circuit
protection devices. Their design stops the flow of
current in the event of a circuit overload. Once a
circuit breaker is tripped, it must be reset
manually. Press the reset button after the breaker
has cooled down.
If the overload that caused the circuit breaker to
trip is still there, the circuit breaker will continue to
stop current flow until the problem is corrected.
The circuit breakers are located in the operator
compartment.
The chart lists the circuit breakers and the
electrical components they protect.
Circuit Breaker
Rating Circuit Protected
CB-1
15 A
Engine and throttle
CB-2
15 A
Vacuum fan, filter
shaker
CB-3
15 A
Operating lights
CB-4
15 A
Hazard light, back-
up alarm
CB-5
15 A
Horn
CB-6
2.5 A
Instrument panel
CB-7
15 A
Heater/defrost,
windshield wiper
CB-8
15 A
Turn Signals
CB-9
15 A
Auxiliary side brush
CB-10
15 A
Cab Pressurizer
FUSE
Fuses are a one-time protection device designed
to stop the flow of current in the event of a circuit
overload. Never substitute higher valve fuses than
specified.
The fuse is located in the operator compartment
under the steering column.
Fuse
Rating
Circuit Protected
FU-1
40 A
Glow plugs
07806
08033
Содержание 355D