OPERATION
Tennant 200 (11–01)
5
TROUBLE SHOOTING
PROBLEM
CAUSE
SOLUTION
Motor does not run.
Machine unplugged or switch not
turned on.
Plug machine in or turn switch to de-
sired speed.
Faulty switch.
Contact Service Center.
Building circuit breaker tripped.
Reset breaker and change to different
circuit.
Faulty power cord.
Contact Service Center.
Faulty wiring.
Contact Service Center.
Blower wheel jammed.
Remove obstruction.
Motor overheated due to intake
screens or exhaust snout blocked.
Turn off dryer, allow motor to cool and
remove blockage.
Faulty capacitor.
Contact Service Center.
Motor overheated.
Intake screens or exhaust snout is
blocked.
Turn dryer off, remove blockage and
allow motor to cool.
Dryer vibrates excessively or
turns erratically or makes unusu-
al sounds.
Serve jolt has caused blower wheeler
shaft or motor mount to be out of align-
ment.
Contact Service Center.
Accumulation of soil on blower wheel.
Clean blower wheel.
SPECIFICATIONS
MODEL
200
LENGTH
584 mm (23 in)
WIDTH
381 mm (15 in)
HEIGHT
508 mm (20 in)
WEIGHT
13.6Kg (30lbs)
BLOWER WHEEL
241 mm (9.5 in) x 241 mm (9.5 in)
AIR MOVEMENT
Low-56.6 m
3
/min.
High-70 m
3
/min.
CHASSIS
Polyethylene
MOTOR
230V/240V, 3A, 0.6kW, 900–1400 rpm
POWER CORD LENGTH
4.6 m (15 ft)
DECIBEL RATING AT OPERATOR’S EAR INDOORS.
68dB(A)
FRONT HEIGHT ADJUSTMENT
38 mm–127 mm (1.5 in–5 in)