background image

               

 

 

 
 

 
 

 

Temperature / Humidity Meter 

 

TM-183/TM-183P 

 
 

                                                                                                                       

 

 

H

HB2TM1830002

 

User’s 

Manual

 

TENMARS ELECTRONICS CO., LTD 

Содержание TM-183

Страница 1: ...Temperature Humidity Meter TM 183 TM 183P HB2TM1830002 User s Manual TENMARS ELECTRONICS CO LTD ...

Страница 2: ...nction 4 4 3 Switch Temperature Scale C F 4 4 4 Data Hold Button 4 4 5 MAX MIN AVG Mode 4 4 6 Backlight 5 4 7 Power ON OFF 6 4 8 DEW POINT WET BULB Relative Humidity Switching 6 4 9 Relative Deduction Value REL 7 4 10 Alarm Intimate Setting Button 7 4 11 Alarm Setting Mode 8 4 12 Enable or Disable Auto Power Off Function 8 4 13 Saving and Reading the Measured Data MEM 8 4 13 1 Saving Measurement D...

Страница 3: ...4 13 2 Reading the Measurement Data Mode 9 4 13 3 Delete the stored data 9 5 Check before Using 10 6 Measurement Method 10 7 CAUTIONS 11 ...

Страница 4: ......

Страница 5: ...umidity and temperature It is perfect for many industrial applications laboratory and other types of work locations 2 CHARACTERISTICS Dual display of temperature and humidity Select between different temperature scales C F Simultaneously hold both temperature and humidity readings Simultaneously hold both Maximum and Minimum and Average readings MAX MIN AVG with time marks Relative subtraction val...

Страница 6: ...200 hours during consecutive use Dimensions 200 55 38 mm L W H TM 183 130 56 38 mm L W H TM 183P Weight 200g excluding the battery Accessories User manual battery carrying case Temperature and humidity probe TM 183P Operating Temperature and Humidity 0 C 60 C 95 RH non condensing Storage Temperature and Humidity 10 to 60 C 70 RH non condensing 3 2 Electrical Specification Temperature 25 C Humidity...

Страница 7: ...ure Scale 8 WET BULB 9 DEW POINT 10 Relative Humidity 11 C Temperature Scale 12 F Temperature Scale 13 Minute Second 14 Day Hour 15 Secondary Display 16 Alarm Indicator 17 Low Alarm Indicator 18 High Alarm Indicator 19 Relative Subtraction Value 20 Stored Data Records or Historical Data Records 21 Record MAX MIN and AVG Enable 22 Auto Power Off Indicator 23 Low Battery Detect ...

Страница 8: ...re Reading Record Button 4 3 Switch Temperature Scale C F Press button to change the temperature unit 4 4 Data Hold Button Press button to enter the Data Hold mode The LCD will display HOLD symbol and hold both the temperature and humidity readings at the same time Press button again to exit this mode 4 5 MAX MIN AVG Mode In normal mode press the button more than one second to enter the MAX MIN mo...

Страница 9: ...tton repeatedly the LCD primary display loop shows the RH DEW WET In the MAX MIN mode press the button the LCD secondary display will switch to the Minute Second M S or Day Hour D H press the button to stop the count time press again to continue count time 4 6 Backlight Press the button to turn on the backlight press this button again to turn it off The auto off backlight time is about 15 seconds ...

Страница 10: ...tion button as below In normal mode Press the and the button less than one second TO read measuring records latest Press the and the button more than one second To delete saved records Press the and the button less than one second TO turn on or turn off Auto power off function In the Reading Measured Data Mode Press the and the button TO turn on or turn off the backlight 4 8 DEW POINT WET BULB Rel...

Страница 11: ...he button more than one second to enter high temperature alarm mode setting in the Alarm Intimate Setting mode press the button repeatedly less than one second the LCD will show the High Alarm Low Alarm RH High Alarm RH Low Alarm in sequence The setting alarm value isn t cleaned up when the thermometer turn off Press the or the button less than one second to increase or decrease current setting va...

Страница 12: ...0 C 60 0 C LOW and HIGH Humidity Alarm 0 0 RH 99 0 RH Temperature Alarm Range 40 0 C 60 0 C 40 0 F 140 0 F Humidity Alarm Range 1 0 RH 99 0 RH 4 12 Enable or Disable Auto Power Off Function The Auto Power Off function is enable when the thermometer on and Auto Power Off symbol shoes If stop any operating after 15 minutes that will execute Auto Power off function Press and button at the same time t...

Страница 13: ...D primary display shows the MEM and the secondary display shows the current record number Press the button to switch displayed temperature relative humidity dew point wet bulb in sequence Press or button to look forward or rearward current recording number and value Long press or button to look forward or rearward current recording value continuously When increase or decrease 20 recording numbers ...

Страница 14: ...tioned correctly Make sure the HOLD sign is not displayed on the LCD 6 Measurement Method Power on the Temperature Humidity Meter If you want to disable the auto power off function please refer to 4 12 section Put the Temperature Humidity Meter into the place wait for measuring Keep the thermometer still about 15 minutes to achieve the best readings According to measuring space and the measuring t...

Страница 15: ...ture Humidity Meter for an extended period of time remove the battery to avoid damage to the thermometer due to the leaking battery fluid Cleaning and Checking of temperature sensor Pay attention to smoke dust on the humidity sensor will let the sensor s response time slow down and causing inaccuracy when measuring Clean up the sensor periodically by simply blowing away the dust particles Do not u...

Страница 16: ...apacity Impedance Tester TACHO Meter LED light meter Temperature Humidity meter Infrared Thermometer Sound level meter Light meter EMF meter UV Light meter RF meter Hot wire Anemometer CO meter Anemometer Lan cable tester CO2 meter Solar power meter Radiation meter Clamp meter Multimeter Phase Rotation tester Digital Insulation tester Our products of high quality are selling well all over the worl...

Отзывы: