TM-183/TM-183P
2
3 SPECIFICATIONS
3.1 General Specifications
Display : Dual LCD display. The maximum value on the
primary display is 1999.
The maximum value on secondary display is 9999.
Low Battery Indicator : When the LCD displays
symbol, please replace the battery.
Sampling Rate : 1 sample per second.
Power Supply : One 9V battery, NEDA 1604, IEC 6F22
or JIS 006P.
Battery Life : 200 hours during consecutive use.
Dimensions : 200 × 55 × 38 mm (L×W×H)(TM-183)
130 × 56 × 38 mm (L×W× H)(TM-183P)
Weight : 200g (excluding the battery)
Accessories : User manual, battery, carrying case ,
Temperature and humidity probe(TM-183P).
Operating Temperature and Humidity :
0°C ~ +60°C, <95% RH. (non-condensing)
Storage Temperature and Humidity:
-
10 to 60°C, <70% RH. (non-condensing)
3.2 Electrical Specification:
(Temperature: 25°C, Humidity : <90% RH)
Temperature Measurement Range :
-40.0°C ~ +60.0°C(-40.0°F - +140.0°F).
Humidity Measurement Range: 0% ~ 100%RH.
3.3 Accuracy:
Humidity : ±3% (20~80%RH,@25
℃
)
±
5% (<20%>80%,@25
℃
)
Temperature : ± 0.8
℃
, ±1.5
℉
.