10
Step 7.
ABC Auto-correct function
Press the
button to enter this item setting
operation.
Press the
or
button to select on/off.
Press the
button to exit this item setting
operation.
Once the ABC function is turned on, it uses
400ppm as the standard and will have
adjusted approximately 30ppm over an
accumulated time of 180 hours; therefore it is
recommended to place it at a well-ventilated
place once the function is enabled.
5.7 Ventilation Formula
CFM/P(inch/minute/person)
CFM/P = 10600/(Cs-Co)
Cs = CO
2
read value, Co = CO
2
outdoor read
value.
L/P/S(liter/second/person)
L/P/S=(CFM/P)*28.32/60