.            Safety information 

Read  the  following  safety  information  carefully  before 

attempting to operate or service the meter. 

Use the meter only as specified in this manual; otherwise, the 

protection provided by the meter may be impaired. 

 

Environment conditions 

1      Altitude up to 2000 meters 

2      Relatively humidity 90% max. 

3      Operation Ambient 0~40

 

 

Maintenance & Clearing

 

1      Repairs  or  servicing  not  covered  in  this  manual  should 

only be performed by qualified personnel. 

2      Periodically  wipe  the  case  with  a  dry  cloth.  Do  not  use 

abrasives or solvents on this instruments. 

 

Safety symbols 

Meter  is  protected  throughout  by  double  insulation  or 

reinforced insulation. 

When servicing, use only specified replacement parts. 

Comply with EMC 

. General Description

 

Thank  you  for  using  our  Sound  Level  Meter.  To  ensure  that 

you  can  get  the  most  from  it,  we  recommend  that  you  read 

and follow the manual carefully before use. 

This unit conforms to the 

IEC61672-1

 type 2, ANSI S1.4 type 

2 for Sound Level Meters. 

This  Sound  Level  Meter  has  been  designed  to  meet  the 

measurement  requirements  of  safety  Engineers,  Health, 

Industrial  safety  offices  and  sound  quality  control  in  various 

environments. 

 

Ranges  from  30dB  to  130dB  at  frequencies  between 

31.5Hz and 8 KHz. 

 

Display with 0.1dB steps on a 4-digits LCD. 

 

With two equivalent weighted sound pressure levels, A 

and C. 

.    Specifications

 

Standard  applied              :

  IEC61672-1

  type  2,  ANSI  S1.4 

type 2 

Frequency range              : 31.5Hz~8KHz 

Measuring level range

     

: 30~130dB 

Frequency weighting 

     

: A/C 

Microphone   

   

: 1/2 inch electret condenser microphone 

Calibration 

       

: Electrical    calibration    with    the    internal 

oscillator (1kHz sine wave) 

Display       

     

  : LCD 

Digital display    : 4 digits 

Resolution: 0.1dB 

Display Up data: 0.5 sec. 

Time weighting : FAST(125mS), SLOW(1 sec.) 

Содержание TEN01073

Страница 1: ...r Sound Level Meter To ensure that you can get the most from it we recommend that you read and follow the manual carefully before use This unit conforms to the IEC61672 1 type 2 ANSI S1 4 type 2 for Sound Level Meters This Sound Level Meter has been designed to meet the measurement requirements of safety Engineers Health Industrial safety offices and sound quality control in various environments R...

Страница 2: ...omatically shuts down after approx 15 minutes of inactivity Power supply One 9V battery 006P or IEC 6F22 or NEDA 1604 Power life About 50hrs alkaline Battery Operation temperature 0 to 40 32 to 104o F Operation humidity 10 to 90 RH Storage temperature 10 to 60 14 to 140 o F Storage humidity 10 to 75 RH Dimensions 210 L X55 W X32 H mm 230g including battery Weight 9V battery carrying case Instructi...

Страница 3: ...ured level is up dated continuously Press once again the button will release the hold and allow a further measurement A weighting C weighting select button A C A A Weighting For general sound level measurements C C Weighting For checking the low frequency content of noise If the C Weighted level is much higher than the A Weighted level then there is a large amount of low frequency noise Time weigh...

Страница 4: ...instrument was not in use for a long time or operated at bad environment 4 Do not store or operate the instrument at high temperature and high humidity environment 5 Keep microphone dry and avoid severe vibration 6 Please take the battery and keep the instrument in low humidity environment When not in use VII Measurement 1 Open battery cover and install a 9 volt battery in the battery compartment ...

Страница 5: ... freezes the reading in the display Press the HOLD button momentarily to activate or to exit the HOLD function 7 Turn OFF the instrument and remove and remove battery when not in use VIII Calibration Procedures Using a standard Acoustic Calibrator 94dB 1kHz Sine wave ...

Страница 6: ... MAX Hold and Data Hold Mode function disable 2 Insert the microphone housing carefully into the insertion hole of the calibrator 3 Open battery cover and remove the battery to adjust the CAL94dB potentiometer of the unit The level display will indicate the desired level Our products are all well calibrated before shipment Recommended Recalibration cycle 1 year Sound Level Meter TEN01073 ...

Страница 7: ... DISPOSAL FOR CONSUMERS OF ELECTRICAL ELECTRONIC EQUIPMENT When this product has reached the end of its life it must be treated as Waste Electrical Electronic Equipment WEEE Any WEEE marked products must not be mixed with general household waste but kept separate for the treatment recovery and recycling of the materials used Contact your local authority for details of recycling schemes in your are...

Отзывы: