background image

4

TIP REPLACEMENT

• 

Replacing the tip should only be done when the iron is switched off and at room 

temperature.

• 

The tip can be changed or replaced by unscrewing the knurled nut barrel.

Caution

: Damage could occur if the iron is left on without the tip inserted.

• 

After removing the tip, blow out any remaining oxide dust that may have formed in 

the tip retaining area of the barrel. 

Warning

: Care should be taken to avoid getting dust in your eyes.

• 

Replace the tip and tighten the knurled nut barrel assembly with your fingers.

• 

Pliers should only be used to tighten the nut if loosening occurs when the iron is 

hot.

• 

Do not over tighten the nut as the element could be damaged.

CLEANING

• 

Cleaning should only be done when the station is switched off and the irons are at 

room temperature.

• 

The iron may be cleaned with a damp cloth and a small amount of liquid detergent 

if necessary.

• 

Never submerse the soldering iron in liquid or allow any liquid to enter the station.

• 

Do not use any chemicals, abrasives or solvents that could damage the soldering 

irons or the station casing.

Calibration method

• 

Both parts of the soldering station have a user calibration potentiometer to make 

adjustment if the displayed temperature is inaccurate after any maintenance or tip 

replacement has been performed. 

• 

Set the temperature to 200

o

C and tin the tip as in a working condition, then using a 

test meter temperature probe, measure the actual tip temperature.

• 

To adjust the display to read accurately using an appropriate insulated screwdriver 

and turn the potentiometer accessible through the access hole marked CAL.

Temperature Scale

• 

To change the display from Celsius to Fahrenheit hold the SET button down while 

switching on the power.

SYSTEM SETTING

De-Soldering IC’s

• 

Attach the most suitably sized nozzle for the size of the IC to the tool.

• 

Adjust the temperature to the required setting and wait a few seconds for the 

actual temperature to be reached.

• 

Use only one hand to hold the hot air tool and one to hold a suitable pick-up wire 

tool. 

• 

Place the pick-up wire under the IC pins.

• 

Put the nozzle over the IC, do not touch the IC or it’s pins with the nozzle.

• 

When the hot air melts the solder tin on the IC pins, lift the pick-up wire to remove 

the IC.

Содержание AT8586

Страница 1: ...1 ESD Safe 2 in 1 Rework Station Model AT8586 ...

Страница 2: ...own completely Do not use the product near flammable items Turn the power off when this product is not in use The soldering iron must be placed on its stand when not in use Before storage turn the power off and allow the product to cool down to room temperature Do not use this product for anything else other than that for which it is designed Children should be supervised to ensure that they do no...

Страница 3: ...re using the soldering iron for the first time dampen the cleaning sponge and place it in the tray on top of the station Keep it damp during use To adjust the temperature press UP or DOWN buttons and the LCD will display the required temperature Press and hold either button to increment the change more rapidly After three seconds the display will switch show the actual tip temperature and then alt...

Страница 4: ...uld damage the soldering irons or the station casing Calibration method Both parts of the soldering station have a user calibration potentiometer to make adjustment if the displayed temperature is inaccurate after any maintenance or tip replacement has been performed Set the temperature to 200o C and tin the tip as in a working condition then using a test meter temperature probe measure the actual...

Страница 5: ...wn the tips or attempt to clean using abrasives If the tip is worn replacement tips are available for this station see our website or catalogue SPECIFICATIONS Soldering Desoldering Power Consumption 50W 700W Input Voltage 220 240V 50Hz Temperature Range 150 480 C 302 896 F 100 500 C 212 932 F Temperature Accuracy 10 C 35 C Temperature Stability 1 C 5 C Air flow rate 120 litres min max Noise 52dB A...

Страница 6: ...be treated as Waste Electrical Electronics Equipment WEEE Any WEEE marked products must not be mixed with general household waste but kept separate for the treatment recovery and recycling of the materials used Contact your local authority for details of recycling schemes in your area Made in China PR2 9PP PO Box 13362 Dublin 2 Man Rev 1 1 ...

Отзывы:

Похожие инструкции для AT8586