3
FUNCTIONS
1
4
5
6
11
10
9
8
7
2
3
1. Test probe +
2. Ground probe
3. LED work light
4. LED voltage display
5. Polarity indicator
6. Contact electrode
7. Single pole phase LED
8.
LED for L/R rotary field
9. Continuity LED
10. Work light button (far side)
11. Battery location
OPERATION
Function/self test
•
Test the voltage tester on a known source before use.
•
Connect test probes to the voltage source.
•
An alert tone should be audible and the LED Rx/Ω (9) should illuminate.
•
The voltage indicator LED’s operate whether batteries are fitted or not but the work
light function and audible sounder requires batteries to function.
Voltage test
•
Connect the test probes across the source under test.
•
The voltage is indicated by the LED’s (4) and an audible tone is output.
•
If the polarity is positive the “+” LED is lit and if the voltage is AC both “+” and “-”
are illuminated.
•
The measured result is displayed by the LED voltage indicators which are
12V, 24V, 50V, 120V, 230V, 400V, and 690V. Voltages lower than 12V are not
displayed.