background image

72-8000 Series Operating Manual

72-8000 Series Operating Manual

1.Summary

    72-8000 is a series of general DC power supplies suitable for laboratory use.

   Both CH1 and CH2 may work in CV or CC mode, and these two modes convert 

automatically according to the load.  CH1 and CH2 have auto tracking function.  In this 

condition, the output of CH2 tracks the output of CH1.  This function is usually used 

when adjustable symmetrical and double polarity power is required.  Both CH1 and 

CH2 display the output voltage or current with a 3-digit-LED meter.
    CH3 is a 5V fixed output.  Its maximum output current is 2A, and it is usually used in 

TTL circuits etc.
    CH1, CH2 and CH3 all have overload protection.

3

Содержание 72-8690 Series

Страница 1: ......

Страница 2: ...72 8000 Series Operating Manual 72 8000 Series DC Power Supply Instruction Manual ...

Страница 3: ...s product please read this manual in detail and keep for future reference This instrument is produced under strict quality control All parts go through screening and ageing and a series of performance testing environmental testing and safety testing In order to guarantee safe use and the best working performance working environment guidelines must be followed 1 ...

Страница 4: ...72 8000 Series Operating Manual Contents 1 Summary 3 2 Specifications 4 3 Applications 5 4 Description of panel 6 5 Applications 7 2 ...

Страница 5: ...d CH1 and CH2 have auto tracking function In this condition the output of CH2 tracks the output of CH1 This function is usually used when adjustable symmetrical and double polarity power is required Both CH1 and CH2 display the output voltage or current with a 3 digit LED meter CH3 is a 5V fixed output Its maximum output current is 2A and it is usually used in TTL circuits etc CH1 CH2 and CH3 all ...

Страница 6: ...CH1 CH2 Current CH3 Current 2A 0A 5A 0A 3A 0A 3A 5V 0V 32V 0V 32V 0V 32V 72 8690 72 8695 72 8700 CH1 and CH2 Load Regulation CV 1X10 4 2mV CC 20mA Ripple and Noise CV 1mVrms CC 1mVrms Adjustable Resolution CV 20mV typical CC 50mA typical Interactive Regulation CV 5X10 5 1mV CC 0 5mA Tracking Error 5X10 3 2mV 4 ...

Страница 7: ...for UK Europe 41ºF to 113ºF for US Power Source AC 220V 10 50Hz 4 UK Europe AC 110V 10 50Hz 4 US Dimensions H x W x D 152mm x 197mm x 305mm Weight Approx 9 5kg MTBF 2000h Accessories Check the meter for any damage or exposed metal parts Packaging should include the following accessory items if any differences or damage please contact the nearby sales offices Power cord 1 pcs Instruction manual 1 pc...

Страница 8: ...NT Adjusts the output current at CC mode MODE Controls two main channels Works in FREE mode or TRACK mode MEASURE Selects the digital meter s display the output voltage or the output current 7 Ground of instrument 8 Output terminal of CH1 9 Output terminal of CH2 10 Output terminal of CH3 11 POWER Push in to turn on the power 4 5 6 3 6 ...

Страница 9: ... button is pushed out each CH1 and CH2 works independently When this button is pushed in CH2 tracks to CH1 The output of CH1 and CH2 are suspended You can set the negative level of output by connecting the reference point to the terminal Each CH1 and CH2 can output from 0V to 32V and from 0V to 3A adjustable 0V to 64V and from 0A to 3A current adjustable in series 0V to 32V and from 0A to 6A adjus...

Страница 10: ...e note The product includes with the power source 220V for UK Europe or 110V for USA Operating Manual content is subject to change without notice Tenma 405 S Pioneer Blvd Springboro Ohio 45066 3001 Phone 1 888 655 5409 Fax 1 800 765 6960 8 ...

Отзывы: