The output of the tone generator can be set to continuous or variable. To change 

the type of output, change the tone type switch position (located in the battery 

compartment).

• 

Identifies telephone cable condition.

• 

Identifies tip and ring connection.

• 

Continuity testing.

OPERATION FUNCTION

Cable / Wire Tracing

1.  Connect the tone generator to the cable. 

a)  For cables terminated at one end, connect the red alligator clip to a wire and  

 

the black alligator clip to equipment ground. 

b)  For un-terminated cables, connect the red alligator clip to one wire and the  

 

black alligator clip to another wire. 

c)  For cables with modular connectors, plug the RJ11 connectors directly into the 

matching cable connectors.

2.  Set the tone generator power switch to the TONE position.

3. 

On the amplifier probe, press and hold the side on/off switch.

4.  Hold the insulated probe tip against the wire in question to pick up the signal 

generated by the tone generator.

5.  Rotate the volume/sensitivity control on the top of the probe for the appropriate 

level and sensitivity to identify and trace the wire.

6.  The tone will be the loudest on the wire(s) connected to the tone generator.

Note:

 A headphone jack is located on the bottom of the probe.

Telephone cable identifying Tip and Ring - using crocodile clips

• 

Switch the tone generator to the OFF position.

• 

Connect the red test lead to one line and the black lead to the other line using the 

alligator clips.

• 

The LED colour indicates the connection to the RED test lead as: 

GREEN = Ring side, RED = Tip side.

Telephone cable identifying Tip and Ring - using the RJ-11 Connectors

• 

Switch the tone generator to the OFF position.

• 

Connect the RJ-11 connector to the phone socket.

• 

The LED colour indicates the condition of the telephone jack wiring. 

GREEN = Jack wired properly, RED = Jack wired with reversed polarity.

Telephone cable identifying line condition

• 

Switch the tone generator to the OFF position

• 

Connect the red test lead to the RING side and the black test lead to the TIP side.

• 

The LED will indicate line condition by: 

GREEN = CLEAR, OFF = BUSY, Flickering YELLOW = RINGING

• 

Switch the tone generator power switch to CONT to terminate the call. 

Continuity testing

• 

Connect the test leads to the wire pair under test.

• 

Switch the tone generator to the CONT position.

• 

The LED will glow bright GREEN for a low resistance or continuity. The LED will 

glow less brightly as the resistance increases and will extinguish at approximately 

10,000ohms.