Tenma 72-3515 Скачать руководство пользователя страница 3

MEASUREMENT DIRECTION OF THE ROTATING MAGNETIC FIELD

It is necessary to measure the direction of the rotating magnetic field in the following 

way:

Insert terminals L1, L2 and L3 of the test pen into the L1, L2 and L3 holes

respectively.

Insert the other terminal of the test pen into the alligator clip.

Allow the alligator clip access to the phases of the three power cables to be

measured.

Afterwards, the LCD will automatically display the sequence of L1, L2 and L3.

SPECIFICATION

Environment

Working temperature

0°C ~ 40°C (32°F ~ 104°F)

Storage temperature

0°C ~ 50°C (32°F ~ 122°F)

Elevation

2000m

Humidity

≤95%

Pollution protection grade

2

IP grade

IP40

Mechanical Specification

Dimensions

123 x 71 x 29mm (4.8 x 2.8 x 1.1in)

Weight

160g

Safety Specification

Electrical safety

Comply with IEC61010/EN61010 & IEC61557-7

Max. operating voltage (Ume)

700V

CAT grade

CAT III 600V

Electrical Specification

Power supply

Provided by the measured device

Nominal voltage

40VAC - 700VAC

Frequency (fn)

15Hz - 400Hz

Current Induction

1mA

Nominal test current (subject to 

each phase)

1mA