NCV NON-CONTACT ELECTRIC FIELD MEASUREMENT

If you wish to measure

whether there is AC voltage

or electromagnetic field,

place the front end of the

clamp head 8~15mm close

to the test piece.

Analogue quantity of

inductive AC voltage is

about ≤ critical voltage

100V, display “EF”, > critical

voltage 100V, prompted by

buzzing.

OTHER FUNCTIONS

Automatic power-off: when measuring, if the rotary button has not been used in 15

minutes, the instrument will automatically power off to save energy.

In automatic power-off mode, turn the rotary button to 

OFF

 and restart the

instrument or press the 

REL

 button.

To turn off the automatic power-off function, press and hold the 

REL

 key, then turn

on the instrument and you will hear 5 buzzes, which means the automatic power-

off function is cancelled.

Turn off and restart the machine and the automatic power-off function will be

recovered.

The buzzer will send out five warnings, one minute before automatic power-off.

A long buzz will be heard before powering off. When the automatic power-off

function is cancelled, you will hear five continuous warnings every 15 minutes.

Buzzer

Press any key or rotate the function switch.

If the function is valid, the buzzer will beep once.

When measuring current out of range, the buzzer will beep to warn it is out of

range (function status as below)

200A gear: current > maximum range, buzzer beeps.

Detecting Low Voltage

When the battery is lower than 2.5V, the low battery symbol appears.

Measurements may not be as accurate once this symbol shows, therefore it is

advisable to replace the battery as soon as possible.

If it is lower than 2.2V, only the battery under voltage symbol shows after starting

up and the instrument will not work.

When the battery supply voltage lowers to 2.6V, the LCD backlight will be in weak

or non-start state, but measurement functions will still work.