background image

5

Voltage or Current channel setting

• 

Press the adjusting control of either Channel 1 or 2 and the corresponding digital 

readout will start blinking. 

• 

Rotate the  contol to increase or decrease the voltage or current displayed on the 

digital readout.

Adjusting Voltage on Channel 3

• 

Press the Channel 3 button for 2 seconds until the current set voltage setting LED 

illuminates.

• 

Pressing repeatedly cycles through the 2.5V, 3.3V and 5V with corresponding LED 

illuminating.to indicate the setting.

• 

To enter Parallel mode, press and hold the PARA button. The PARA LED on the 

display will illuminate to confirm the setting.

• 

Initially default master channel is channel 2 with channel 1 as slave and shielded.

• 

Press the ON/OFF button to switch the output on or off.

• 

Connection terminals are shown in the diagram below. 

VOLTAGE OR CURRENT MODE

Содержание 72-13300

Страница 1: ...1 DC Power Supply User Manual Model No 72 13300 and 72 13310 ...

Страница 2: ... Do not discharge static electricity This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children should be supervised to ensure that they do not play ...

Страница 3: ... Mains power socket Rear Panel Parallel button Series Button Parallel LED Series LED Voltage Adjustment Controls Current Adjustment Controls Channel 3 Voltage Selector Front Panel Channels 1 2 output OFF button Ch 3 Voltage Indicator LEDs Ventilation Grille ...

Страница 4: ...l illuminate to confirm the setting Initially default master channel is channel 2 with channel 1 as slave and shielded Press the ON OFF button to switch the output on or off Connection terminals are shown in the diagram below SERIES OR PARALLEL OPERATION FRONT LED DISPLAY Voltage display Current display Display R ...

Страница 5: ...seconds until the current set voltage setting LED illuminates Pressing repeatedly cycles through the 2 5V 3 3V and 5V with corresponding LED illuminating to indicate the setting To enter Parallel mode press and hold the PARA button The PARA LED on the display will illuminate to confirm the setting Initially default master channel is channel 2 with channel 1 as slave and shielded Press the ON OFF b...

Страница 6: ...le 20 20M Voltage 1mVrms 2mVrms Current 3mArms 3mArms Temp Coefficient Voltage 150ppm 150ppm Current 150ppm 150ppm Read Back Accuracy Voltage 10mV 10mV Current 1mA 1mA Read Back Temp Coefficient Voltage ISOppm ISOppm Current ISOppm ISOppm Reaction Time Voltage Rise 100ms 100ms Voltage Drop 100ms 10 rated load 100ms 10 rated load Load Regulation of Parallel Voltage 0 1 0 1V Load Regulation of Serie...

Страница 7: ...liquid to enter the case Do not use any chemicals abrasives or solvents that could damage the power supply casing Changing the fuse Replace the fuse only with one of exactly the same type and rating Disconnect the mains power and unplug the mains lead before replacing the fuse Model 110 120V 220 230V 72 13300 T4A 250V T2A 250V 72 13310 TSA 250V T3A 250V ...

Страница 8: ...be treated as Waste Electrical Electronic Equipment WEEE Any WEEE marked products must not be mixed with general household waste but kept separate for the treatment recovery and recycling of the materials used Contact your local authority for details of recycling schemes in your area Made in China PR2 9PP PO Box 13362 Dublin 2 Man Rev 1 1 ...

Отзывы: