Model  72-10395 Operating Manual

 

 

Press the button,  then the current reading is set as reference value which will be 
automatically subtracted from subsequent measurement readings. Press it again to exit 
and return to normal measuring mode. This function is not available during frequency 
and duty cycle measurement. 

3.

 

Data Hold (HOLD Button): 

Press this button to hold displayed values; press it again to exist hold status and return to 
normal measuring mode. 

4.

 

Hz/% Measurement: 

Press the button to switch to Hz or % measurement under DCV and ACV ranges(the Hz/% 
buttoncan be used for measuring switching  between  frequency and duty cycle); when 
Hz/% measurement is finished, the meter will return to DCV or ACV measuring mode 
with the range  being  400mVand  4V  respectively  and meanwhile “AUTO” icon on LCD 
disappears. If high voltage measurement is needed at the moment, please turn rotary 
knob or turn off the meter to reset autorang for V

, μA, mA 

measurement before starting 

the test. 

Under Hz/% mode, press Hz/% button to switch between Hz and % measurement.

 

 

IV.

 

Technical Specifications 

A.

 

General specifications 

1.

 

Max voltage between the voltage input terminal and ground: 600Vrms or 600 DCV 

2.

 

Range selection: Auto 

3.

 

Measuring rate: 3 times per second 

4.

 

Max display: 3999; 3 3/4 digits 

5.

 

Over range display:“OL” 

6.

 

Polar indication: “

-

”icon for negative input 

7.

 

Low battery display: “      ” icon on LCD 

8.

 

Internal battery: one Lithium-manganese button cell, 3V, model: CR2032 

9.

 

Operating temperature: 0

~40

(32

~104

 ), h

umidity ≤75%

 

Storage temperature: -10

~50

 (14

~122

Operating altitude h

eight: ≤2000m

 

10.

 

Dimension: 109.8mm x 58.2mm x 10.8mm 

11.

 

Weight: about 76g (including test probes and battery) 

12.

 

Auto Power Off 
The meter will  enter the standby mode ifno  operation with the rotary switch and 
buttons within about 30 minutes. In the standby mode, it can be activated (i. e. enters 
the working mode) by turning the rotary switch or pressing any buttons on the front 
panel.  But pressing SELECT button to activate the meter will cancel Auto Power Off 
function. 

B.

 

Accuracy specifications 

Accuracy: ± (a% r b digits), 1-year warranty period 
Ambient temperature: 23

±5

 

Relative humidity:

≤75%

 

 

Содержание 72-10395

Страница 1: ...Model 72 10395 Operating Manual Pocket Size Digital Multimeter Model 72 10395 ...

Страница 2: ...unction descriptions 2 Ⅳ Technical Specifications 3 A G eneral specifications 3 B A ccuracy specifications 4 Ⅴ Operations 5 1 D C voltage measurement 5 2 A C voltage measurement 5 3 R esistance measurement 6 4 F requency and duty cycle measurement 6 5 D iode and continuity measurement 6 6 C apacitance measurement 7 Ⅵ Battery Replacement 7 ...

Страница 3: ...ful when the measured voltage is above DC 60V and AC 42V RMS so as to avoid electric shock 5 Do not use the meter before the back cover is well installed 6 No measured signal should be above the specified limits 7 No stall change of rotary knob is allowed during measurement 8 Do not change internal wiring without authorized permission As it will cause meter damage and user injury 9 To ensure accur...

Страница 4: ...e figure 1 1 LCD display 2 Selecting resistance capacitance diode or continuity measurements SELECT button 3 Relative value measurement REL button 4 Rotary knob 5 Hz measurement DCV ACV and Hz stall 6 Data Hold 7 Positive input end red test probe 8 Negative input end black test probe B Button Function Descriptions 1 SELECT button It is used for function switching among resistance capacitance and b...

Страница 5: ...he test Under Hz mode press Hz button to switch between Hz and measurement IV Technical Specifications A General specifications 1 Max voltage between the voltage input terminal and ground 600Vrms or 600 DCV 2 Range selection Auto 3 Measuring rate 3 times per second 4 Max display 3999 3 3 4 digits 5 Over range display OL 6 Polar indication icon for negative input 7 Low battery display icon on LCD 8...

Страница 6: ... Range Resolution Accuracy a readings b digits Input Protection Description Capacitance CAP F 4 000nF 0 001nF 600V AC For reference only 40 00nF 0 01nF 4 3 Measuring in relative measuring mode the open circuit voltage is around 0 45V 400 0nF 0 1nF 4 000μF 0 001μF 40 00μF 0 01μF 100μF 0 1μF 5 10 When measured capacitance is above 100μF the reading is for reference only Frequency Hz 99 9Hz 0 1Hz 0 5...

Страница 7: ...s appear on LCD 2 Connect the black test probe to the cathode of the power to be measured and the red test probe to the anode of the power to be measured 3 Read measuring results displayed on LCD 4 Reverse test probes in measurement then LCD will display negative readings Figure 2 Figure 3 2 AC voltagemeasurement See Figure 3 1 Turn the knob to ACV stall Auto and AC icons appear on LCD 2 Connect t...

Страница 8: ...veral seconds to get stable readings 4 Frequency and duty cyclemeasurement See Figure 5 1 Turn the knob to Hz DCV or ACV stall 2 Press Hz button to access frequency measurement 3 Connect test probes in parallel to frequency signal source to be measured 4 Read measured results on the display 5 Press Hz button again to access measurement Notes The measured resolution based on frequency and waveform ...

Страница 9: ...ct relative value measuring mode 3 Press REL button once 4 Connect test probes to the capacitance to be measured and read data on LCD Notes Fully discharge capacitance before measurement As for in line capacitance measurement it is required to turnoff all power supplies in the measured circuit and fully discharge all capacitors If the capacitance being measured has polarity ensure that the red pro...

Страница 10: ...Model 72 10395 Operating Manual 8 Tenma Test Equipment 405 S Pioneer Blvd Springboro Oh www tenma com ...

Отзывы: