F. Capacitance Measurement
(See figure 8)
Warning
To avoid damage to the Meter or to the equipment
under test, disconnect circuit power and discharge
all high-voltage capacitors before measuring
capacitance. Use the DC Voltage function to confirm
that the capacitor is discharged.
To measure capacitance, connect the Meter as follows:
1. Insert the red test lead into the
Hz mV
terminal and
the black test lead into the
COM
terminal.
2. Set the rotary switch to
.
3. Connect the test leads across with the object being
measured. The measured value shows on the display.
26
Model 72-1016: OPERATING MANUAL
(Figure 8)
This Manual: http://www.manuallib.com/file/2587080