12
OPERATING GUIDELINES
2. Wait for the display to change to “E999”. This denotes that the
system is waiting for the system lock PIN code.
3. Press the increase or decrease button to adjust to your previously
selected PIN code. Press the set button to confirm PIN code entry. If
PIN code is correct system lock would be disabled, if PIN entered is
incorrect the display would revert to “E999”.
4. If no PIN code is entered within a few seconds the system would
revert to showing the actual temperature.
E. TEMPERATURE SCALE
The displayed temperature can be toggled between the centigrade
scale or the Fahrenheit scale.
To switch between the two scales follow these procedures:
1. While the unit is ON , press and hold the set button.
2. Wait for the display to change to “A###”, then repeatedly press the
“SET” button until “F C°” or “F F°” is displayed. This denotes that we
are now configuring temperature scale settings.
3. “F C°” indicates that the current system scale is Centigrade. “F F°”
denotes the selected temperature scale is the Fahrenheit scale.
Press the increase or decrease button to select between the two
temperature scales.
4. To save the temperature scale settings, repeatedly press the SET
button until the display shows the word “SAVE”. Press the increase
button to save and exit from the system configuration mode.
◆
The temperature display would change according to the scale
selected. A suffix “F” /“###F” indicates the Fahrenheit scale, while
“C” /“###C” indicated the Centigrade scale.
E. AUTOMATED CALIBRATION
The system’s automated calibration can only be activated and util-
ized if attached to our separate auto-calibration adaptor. For detailed
information on how to utilize this feature please refer to the manual pro-
vided with the auto-calibration adaptor.
5
SAFETY PRECAUTIONS
●
Check each component after opening the package to make sure
everything is in good condition. If there are any suspected damage,
do not use the item and report the issue to your vendor.
●
Turn OFF the main power switch and unplug the device from
power source when moving the device.
●
Do not strike or subject the main unit (and all its components) to
physical shock. Use carefully to avoid damage to any part.
●
Handle with care.
- Never drop or sharply jolt the unit.
- Contains delicate parts that may break if the unit is dropped.
●
Make sure the equipment is always grounded. Always connect
power to a grounded receptacle.
●
Temperature may reach as high as 480°C when switched ON.
- Do not use the device near flammable gases, paper and other flammable
materials.
- Do not touch heated parts, which can cause severe burns.
- Do not touch metallic parts near the tip.
●
Disconnect the plug from the power source if the unit will not be
used for a long period.
- Turn off power during breaks, if possible.
●
Use only genuine replacement parts.
- Turn off power and let the unit cool down before replacing any part.
●
The unit may produce a small amount of smoke and unusual odor
during initial usage. This is normal and should not yield any nega-
tive result when reworking.
●
Soldering process produces smoke — use on well ventilated
places.
●
Do not alter the unit, specifically the internal circuitry, in any man-
ner.
CAUTION:
Improper usage can cause serious injury to
personnel and/or damage to equipment and work area. For