7. Changing the temperature unit of measure:
In the power off condition, press and hold knob “#”, then turn on the station,
the temperature unit will be changed between “°C” and “°F” and store automatically
8. Error Notification:
When “H-E” or “S-E”is displayed on the screen, there is some wrong in heating element or the circuit.
(Diagrams 5 and 6). Turn off the unit and follow the instructions to replace the heating element.
9. Replacing the heating element
a. Power off the unit and unplug the device. Wait for the heating element to cool down.
b. Loosen the nut (1)
c. Remove the tip retainer (2) and soldering tip (3)
d. Unscrew heating contact (4), remove grouping spring(5)
e. Remove the full heat wire group (6)
f. Replace the heating element
g. Reverse the process to secure the heating element in the handle
h. Preferred heating element : CBB018722