2.4. SSB Mode Operation

Be   sure   the   TMB   switch   is   in   the   Middle 
position. To begin SSB operation toggle the 
MOD button to either the LSB or USB for the 
mode of you wish to operate.  The Argonaut 
VI   will   display   the   last   mode   you   have 
selected   when   toggling   through   the   bands. 
Note:   Remember to set the PBT (4) control 
to   the   center   of   rotation   so   the   side   band 
signal is centered in the desired filter.   This 
results in a starting point for proper side band 
audio.  

Monitor Level (3, 5, 7)

To monitor your SSB, audio input levels, or 
Speech   Processing   level,   a   built   in   monitor 
can be heard best with a set of headphones 
connected  to the Argonaut VI.   To activate 
the   monitor   feature   you   must   first   set   the 
Argonaut   VI   into   either   LSB   or   USB.     Be 
sure the TMB button is in the Middle.  Rotate 
the bandwidth   control until switched to the 
CW position.  Press the BAN button and you 
will see (

nnon

 

LUL

) on the screen.  The level 

can be adjusted from the main VFO knob and 
a   level   amount   will   be   displayed   on   the 
bottom   center   of   the   screen.   0   means   no 
Monitor output, and non-zero means that % 
will be added to the speaker and headphone 
outputs. The level is still active whenever a 
non-zero value is used and will be heard in 
voice   transmit   modes   when   transmitting 
regardless   of   whether   the   monitor   is   in   the 
adjustment mode or not.

Speech Processing (3, 5, 8)

Be  sure  the  Argonaut  VI  is in  the  USB or 
LSB mode.  To turn the Speech Processor on 
be  sure  the  TMB  switch  is  on the  Bottom. 
Rotate the bandwidth   control until switched 
to   the   CW   position.   Press   the   MW   (PRE) 
button.  The screen will display (

SP PrOC

)

Adjust the desired amount of processing with 
the main VFO knob 0-9.  When set at zero the 
procesor will be turned off.  Any setting from 
1-9 will be active and remain on all the time 
when   in   side   band   modes.     To   exit   simply 
press   MW   (PRE)   and   the   main   frequency 
display will be brought back on screen.

Remember: When you are finished making 
adjustments to Monitor Level and Speech 
Processing   values,  turn   the   BW   pot 
clockwise from the CW position to return 
the   Argonaut   VI   to   normal   operational 
modes.

Auto Notch (9)

The   Argonaut   VI   provides   an   Automatic 
Notch  feature.  AN will  operate  in  CW and 
Voice modes. To turn it on and off requires 
that   you   select   USB   or   LSB   mode.   Then 
rotate the bandwidth control until switched to 
the CW position. Press the NR(9) button. This 
toggles the AN setting. There is no indication 
on the front panel for Auto Notch. When you 
press the NR (9) button, 1 beeps means that 
Auto Notch is disengaged, and 2 beeps means 
that Auto Notch is engaged. Auto Notch state 
is not remembered during a power cycle, and 
it will default to Off upon power up.

539 / Argonaut VI Users manual

Release 0.10  – November 13, 2012

Part #74479
Printed in USA

13

1

2

3

4

5

6

7 8

10

9

Figure 2-1 539 Front Panel- (with indexes)

Argonaut VI

Содержание ARGONAUT VI 539

Страница 1: ...quency to Memory 8 11 NR NB 9 Noise Reduction Noise Blanker 12 2 4 SSB Mode Operation 13 Monitor Level 3 5 7 13 Speech Processing 3 5 8 13 Auto Notch 9 13 MIC Connector 14 Mic Gain and Line Gain 10 15...

Страница 2: ...Linear Amplifier 25 4 Accessory Devices 25 4 1 List of Optional Accessories For The Argonaut VI 25 4 2 Using the 712 USB Soundcard Interface 25 5 Specifications 26 5 1 Transceiver Specifications 26 5...

Страница 3: ...ional hardware and accessories listed in Table 1 3 1 come standard with your new Argonaut VI Look over the items listed and refer to the 5 digit Ten Tec part number and description should you find the...

Страница 4: ...f the transceiver before starting or shutting off the DC source equipment These recharging devices often generate large voltage spikes that can damage the transceiver 1 5 A word about grounding A good...

Страница 5: ...ision The SPU samples the low IF at 96K samples per second and applies the resulting data to a digital signal processor Numerical algorithms running in the digital processor accomplish additional sele...

Страница 6: ...alculated on the bridge in the Argonaut VI When in transmit the bar graph meter will display your power output peaks When you wish to view the SWR ensure that the three position switch 5 labeled with...

Страница 7: ...ti function buttons will perform Main Encoder for various adjustments 6 There is a single Main Encoder on the front panel that is used primarily for adjusting the tuned frequency It also serves as the...

Страница 8: ...olume of the internal speaker and also for the headphones if one is plugged into the rear jack Rotating the AF Gain control clockwise will increase the volume to a maximum of 100 at full clockwise rot...

Страница 9: ...r the greatest selectivity and interfering signal rejection Band 7 Be sure TMB switch is in Middle position To change bands or toggle through the Ham bands press the BAN button and the next Ham band w...

Страница 10: ...ized in a given band will be recalled when that band is used again Remember AM mode will not be displayed or active unless EaD has been selected within the configuration menu Headphones 20 on rear pan...

Страница 11: ...ry number To exit MEM mode without saving any changes quickly tap the MR NR button to exit back to your VFO frequency and mode Storing a Frequency to Memory 8 To store a memory channel be sure the TMB...

Страница 12: ...tch is in the Middle position Ensure that the bandwidth control is pointing to 12 o clock To adjust how aggressive the noise blanker operates press the NR button 1 beep Press and hold the NR button on...

Страница 13: ...de or not Speech Processing 3 5 8 Be sure the Argonaut VI is in the USB or LSB mode To turn the Speech Processor on be sure the TMB switch is on the Bottom Rotate the bandwidth control until switched...

Страница 14: ...hum or RFI into transmit audio signal We recommend that the case of the microphone also be tied to chassis ground on the transceiver via a shielded cable to pin 5 This is to help assure stray RF does...

Страница 15: ...unless a master reset is done To toggle between microphone input and Auxilliary Line input simply press the USR MOD button once for microphone gain or hold down this button for Line Gain If other mic...

Страница 16: ...return to regular VFO mode and your settings are stored CW Sidetone Frequency Ensure that the bandwidth control is rotated fully counter clockwise in the CW Clicked position Switch the TMB switch to t...

Страница 17: ...dio derived digital mode operation you will either be in USB or LSB To set up the Argonaut VI for digital communications using the ACC 1 rear connector you must first turn on the ACC 1 line input To s...

Страница 18: ...ntrol programs the Flash Update Utility etc If required you can change the actual port number being used to a lower number if required Sometimes the update program on some computers will require a por...

Страница 19: ...wn in the following table Item Settings Notes F1 nO none 60 6KHz 29 2 9KHz 07 700Hz Refer to Section Optional Filter Installation for more information on physical installation of each filter Valid opt...

Страница 20: ...rts up in flash update mode you will see the TX ALC LED flash on for a second then back off then back on for a second IF the USB Cable is connected and the drivers are working properly in the PC then...

Страница 21: ...be installed in slot F3 8 Locate the F1 F2 F3 slot to insert the specific filter Refer to Figure 2 10 1 This is according to the filter slots on the circuit board text The order is shown on the circu...

Страница 22: ...ttings are not immediately written into the non volatile memory every time that the user changes a setting When a user setting is changed this value will be stored 15 seconds after the user has made h...

Страница 23: ...ut VI is equipped with one DC output connectors to power various accessories The output power is limited to 0 5 Amp maximum USB 17 The rear panel on the Argonaut VI has a Standard B type USB connector...

Страница 24: ...transmitting In CW Mode this pin can be used as a keying input for an external device such as an external keyer or a computer running a CW generator program 4 Line Out Output Line Level Audio output...

Страница 25: ...aut VI permits the usage of several optional accessories At the time this manual was printed the list includes the following items Item Part Model Number 6 KHz Filter 2003 700 Hz Filter 2006 USB Sound...

Страница 26: ...Ext Key Clock Data Enable Ground DC Power Connector AMP MATE N LOCK 2 pin Fuse Automotive Blade Style 7 5 A 32V Tuning Step Size 10 100 1000 speed sensitive VFO Lock Frequency Stability 0 5 PPM over o...

Страница 27: ...off IF Frequencies 1st 9 0018 MHz 2nd 22 2 kHz 3rd 0Hz DSP IF Rejection Typical 74 dB 1st IF Image Rejection Typical 59 dB 2nd IF Image Rejection Typical 69 dB Other Spurious Response Rejection 80dB B...

Страница 28: ...TT or VOX on SSB AM QSK on CW CW Keyer Type Internal Curtis Mode A or B Selectable CW Rise and Fall Times 5ms CW Offset adjustable CW Keyer Speed 5 50 WPM adjustable weighting Current Drain 3 amps at...

Страница 29: ...NT PANEL CPU LCD DISPLAY LCD DRIVER KEYPAD ENCODER EEPROM PWR ON OFF 13 8 V MIC MIC AMP MIC AUDIO REC AUDIO SPEAKER AMP SPU CODEC DSP CLK DAT ENA TO SWITCHES PRESELECTOR R T LINE IN OUT 22 5 kHz TX IF...

Страница 30: ...e harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the foll...

Страница 31: ...lem Distorted SSB transmit or Perceived RFI in the shack Be certain the mic gain is set properly The ALC LED should flash on voice peaks but not remain continuously lit in SSB modes Check the setting...

Страница 32: ...amplifier temperature of 70 degrees C or higher In this condition the radio will stop transmitting until the final amplifier temperature is back down to a reasonable level Problem Get a PORT in use w...

Страница 33: ...ipping both ways If you want to return a piece of equipment purchased from Ten Tec please call the sales department at 865 453 7172 from 8 a m to 5 p m Eastern time Mon Fri and obtain a return merchan...

Отзывы: