Tempstar DFC4A3 Скачать руководство пользователя страница 7

OWNER'S MANUAL                      Duct Free Split System - High Wall: DFS4(A/H), DFC4(A/H)3, DFF4(A/H)H

421 02 9301 00                                                                                                                                         7

REMOTE CONTROL FUNCTIONS

Pressing the On/Off Button

ON/OFF

Indicator

A

UTO

S

ET TE MP.

CLOCK

SPEED

AUTO

When the air conditioner is not in operation, the remote
control will display the last set point, mode, and time.

Press the On/Off button to start the unit.

- The unit will start in the last operating mode and 

set point.  The ON/OFF indicator will appear.

Press button On/Off to stop the unit.  

- All indicator lights on the unit will go out, and the 

remote control will display the set point, mode, and time.

NOTE: 

If the On/Off button is pressed too soon after a stop,

the compressor will not start for 3 minutes due to the
inherent protection against frequent compressor cycling.
The unit will only emit an audible beep when the signals are
received correctly.

Selecting an Operating Mode

Use the Operating Mode button to select one of the
available modes.

H

A

T

FA

N

A

UTO

S

ET TE MP.

CLOCK

SPEED

AUTO

C

 OOL

DR

 Y

Operating

Mode

A

UTO

C

OOL

DR

Y

H

E

A

T

FA

N

A07548

Setting the Room Temperature Set Point

Pressing the increase temperature set point 

 

and

decrease 

 

buttons will raise or lower the temperature.

The unit will confirm signal receipt with a beep and the value of
the set temperature on the display will change accordingly.

The temperature can be set between 62

F (17

C) and 88

F

(31

C).

NOTE: 

In Cooling mode, if the temperate selected is higher

than the room temperature, the unit will not start.  The same
applies for the Heating mode if the selected temperature is
lower than the room temperature.

Selecting the Fan Speed

A

UT O

S

ET TEMP.

CLOCK

SPEED

AUTO

LOW ME

D

 

HI

G

H

Fan Speed

The fan speed can be selected by pressing the 

FAN

SPEED

 button.

NOTE: 

When the unit is on, the fan will run continuously in

cooling or heating.  When in heating, there might be situations
where the fan will slow down or shut off to prevent cold blow.

Selecting the Horizontal Direction Louver Position

In order to optimize comfort, the horizontal louvers can
operate in a preset range as shown below.

Cooling

Heating

The horizontal louvers can be adjusted using the remote
control.  The horizontal louvers can be either stationary or
moving continuously.
Press the AIR DIRECTION button repeatedly to choose one
of the louver positions. Every time the Air Direction button is
pushed, the louver will swing by 6 degrees.
In the Cooling, Dehumidification, and Fan Only mode, the
louver will swing in the cooling range.  In the Heating mode,
the louver will swing in the heating range.

NOTE: 

Always use the remote control to adjust the louver

position, otherwise abnormal operation may occur.  If the
louver is manually adjusted out of its range, turn the unit off
and then on again.

Auto Swing

To have the louver moving continuously, push the SWING button.

Push again to stop the louver.

Selecting Vertical Direction of the Louver

The vertical louvers can be adjusted manually to direct the
airflow to achieve the optimal comfort in the space.

A07543

Timer Function

TIMER ON (to start the unit) and TIMER OFF (to stop the
unit) can be used separately or together.

Timer ON only

A

UTO

S

ET TE MP.

SPEED

AUTO

TIMER ON

Timer ON

This function will allow the unit to start automatically after a
set number of hours.  The TIMER ON can be set while the
unit is on or off.
UNIT ON
-Press the TIMER button once. The current time flashes
next to the TIMER ON. Press the Temp 

 

or 

 button to

set the desired “Time On”.  Every time the 

 or

  

 button is

pushed, the time increases or decreases by 10 minutes.
- When the TIMER ON is set, the TIMER light on unit
illuminates.  The unit will shut off and it will start at the set
time.
UNIT OFF
- Set the timer described in the UNIT ON section.
- The unit will start at the set time.
To cancel Timer setting, press the Cancel button.

Содержание DFC4A3

Страница 1: ...mation Manual carefully before installing and using this appliance and keep this manual for future reference For your convenience please record the model and serial numbers of your new equipment in the spaces provided This information along with the installation data and dealer contact information will be helpful should your system require maintenance or service UNIT INFORMATION Model ____________...

Страница 2: ...authorized kits or accessories when modifying this product WARNING GENERAL The high wall fan coil unit provides quiet maximum comfort In addition to cooling and or heating the high wall fan coil unit matched with an outdoor condensing unit will filter and dehumidify the air in the room to provide maximum comfort IMPORTANT The high wall fan coil unit should be installed by authorized personnel only...

Страница 3: ...ctive cable Service valve 1 3 4 5 6 7 8 9 11 12 13 2 INDOOR UNIT OUTDOOR UNIT Remote controller holder 10 10 Indoor Outdoor Unit 1 2 4 5 6 3 8 7 9 10 11 12 13 14 1 2 4 5 6 3 8 7 9 10 11 12 13 14 MODE FAN SPEED TEMP A IR DIRECTIO N SWING LE D SLE EP TURBO CLOCK TIM ER CANCEL RESE T F C AUTO C OOL DRY HEAT FAN SET TEMP CLOCK TIMER ON TIMER OFF SPEED AUTO LOW MED HIGH ON OFF MODE Button ON OFF Button...

Страница 4: ... The actual shape of your air conditioner may be slightly different but the operation instructions are the same Remote Control Display A U T OC O O L D R Y H E A T F A N S E T T E M P CLOCK TIMER ON TIMER OFF SPEED AUTO LOW MED HIGH Clock Display Timer Display Lock Display Sleep Display Fan Speed Indicator Transmission Indicator Mode Display ON OFF Indicator Temperature Setting 1 TRANSMISSION Indi...

Страница 5: ...tment 3 Replace battery compartment cover NOTE 1 When replacing batteries do not use old batteries or a different type battery This may cause the remote control to malfunction 2 If the remote is not going to be used for several weeks remove the batteries Otherwise battery leakage may damage the remotecontroller 3 The average battery life under normal use is about 6 months 4 Replace the batteries w...

Страница 6: ... decrease temperature set point buttons until the desired temperature appears on screen 5 Select the desired fan speed by pressing the FAN SPEED button to select desired fan speed NOTE If unit is operating in Dry mode the auto fan speed will be displayed 6 Set the airflow direction When the unit is turned on the louvers default to the cooling or heating position The user can adjust louver position...

Страница 7: ...ling or heating When in heating there might be situations where the fan will slow down or shut off to prevent cold blow Selecting the Horizontal Direction Louver Position In order to optimize comfort the horizontal louvers can operate in a preset range as shown below Cooling Heating The horizontal louvers can be adjusted using the remote control The horizontal louvers can be either stationary or m...

Страница 8: ... will be cancelled if any button on the remote control is pressed Heat Mode Same as cooling mode but set points will be lowered by 1 8 F 1 C Turbo Mode This function is available in COOL mode on 9k and 12k cooling only units Use the TURBO mode to cool the room rapidly Press the TURBO button An audible beep will be heard The fan will run on high speed The TURBO mode terminates automatically 20 minu...

Страница 9: ...UIPMENT DAMAGE HAZARD Failure to follow this caution may result in equipment damage When cleaning the front panel do not use water hotter than 105 F 40 56 C and do not pour water onto the fan coil Do not use abrasive or petroleum based cleaners as they may damage the front panel CAUTION Indoor Unit Front Panel To clean the front panel on the indoor unit wipe the outside with a soft dry cloth If ne...

Страница 10: ...ur service representative Call your service representative Cooling is Not Working Properly The filter is blocked with dust Temperature is not set properly A window or door is open The outdoor unit is obstructed The fan speed is too low The operation mode is in Fan instead of Cool Clean the air filter Check the temperature and reset if necessary Close the window or door Remove the obstruction Chang...

Отзывы: