Tempo Fitness FSP200 Скачать руководство пользователя страница 27

FSP200

27

Tempo Communications Inc.

1390 Aspen Way • Vista, CA 92081 USA • 800-642-2155

Maintenance INFO

 • Total Fusion Count: Displays the total number of splices made on the fusion splicer. 

 • Software Version: Diplays the software version of the splicer. 

 • Serial Number: Displays the fusion splicer serial number. 

The FSP200 can make and save up to 100 screen shots. To make a screen shot:

 1. Press and hold the Menu key.

 2. Press Enter to confirm.

Set

This menu is used to set system settings.

Language

Navigate to select the desired language.

Beep Switch

Set or disable the beeper notification.

Screen Direction

Set for front or back operation.

LCD Auto Turn-Over

Enable or disable the splicer for the LCD to display the splice screens when the LCD screen is tilted to a different axis.

Auto Heat Switch

When enabled the heater will automatically start when the heater door is closed.

Power Save

The Power Save function conserves energy by turning off the LCD and/or the entire splicer.

Monitor Shut Down

The user can select or disable when/if the LCD can be turned off after a period of inactivity. The time is adjustable from 0-20 

minutes.

Splicer Shut Down

The user can select or disable when/if the LCD can be turned off after a period of inactivity. The time is adjustable from 0-20 

minutes.

LCD Brightness

The brightness of the LCD can be adjusted to compensate for ambient lighting conditions. 

Set Calendar

The date and local time can be set.

Содержание FSP200

Страница 1: ...NUAL Read and understand all of the instructions and safety information in this manual before operating or servicing this tool 52063481 REV 6 2019 Tempo Communications Inc 01 20 FSP200 Optical Fiber F...

Страница 2: ...ing Procedure 14 Heating Protection Sleeve 15 Cooling Tray 16 Splice on Connectors 16 Button Functions 17 Appendixes 17 Section 3 Menu Operation 18 Splice Mode Menu S Mode 18 Heater Mode Menu H Mode 2...

Страница 3: ...ice loss Contents List FSP200 fusion splicer 250 micron adapter pair 900 micron adapter pair SC LC splice on connector adapter SOC Oven adapter Spare electrodes one pair AC adapter power supply with N...

Страница 4: ...ove Instrument Cover Do not remove the cover of the unit for any reason It contains no user serviceable parts SAFETY ALERT SYMBOL This symbol is used to call your attention to hazards or unsafe practi...

Страница 5: ...e injury or death Electric shock hazard Use only AC adapter or battery charger designed for this splicer Using an improper AC power source could cause fuming electric shock or equipment damage Do not...

Страница 6: ...ock or equipment damage This tool uses a three prong core AC power cord that contains an earthed ground safety mechanism This tool must be grounded Use only the supplied power cord Never use a two pro...

Страница 7: ...battery It contains no user serviceable parts Failure to observe these precautions may result in injury and may damage the unit Do not store tool in areas of extremely high temperature and humidity D...

Страница 8: ...discoloration damage or deterioration This tool requires no lubrication Oil or grease may degrade the splicing performance and damage the splicer This equipment must be repaired or adjusted by a qual...

Страница 9: ...ut USB port Input Wind Protector LED Power Unit Dock Description of Products 2 Description and Function of Splicer Front Side of OFS 95 Back Side of OFS 95 Output USB port Input Wind Protector LED Pow...

Страница 10: ...FSP200 Tempo Communications Inc 1390 Aspen Way Vista CA 92081 USA 800 642 2155 10 Top View Description of Products Top Side of OFS 95 Keypad of OFS 95...

Страница 11: ...Turn off the splicer Push the release button located on the side of the splicer body and remove the battery Two Methods of Checking Remaining Battery Capacity If the battery is already installed in th...

Страница 12: ...analyzing fiber profile and the splicing condition is chosen for the type of fiber The types of fibers covered by AUTO are all the conventional fibers such as SMF G652 BIF G657 NZDSF G655 MMF G651 et...

Страница 13: ...upplied with the splice on connectors Clean optical fiber with alcohol soaked gauze or lint free tissue Dust particulates can enter the protection sleeve resulting in a fiber break or attenuation incr...

Страница 14: ...or fiber chipping is detected the beeper sounds and an error message warns the operator The splicing procedure pauses If no error message is displayed the below stated end face conditions are used fo...

Страница 15: ...n is first started or if the splicing environment has changed it is recommended that the technician perform an arc calibration 1 Place cleaved fibers into the splicer 2 Press and navigate to the Maint...

Страница 16: ...inspect the finished sleeve to verify that no bubbles or debris dust is present in the sleeve Cooling Tray Place the splice into the cooling tray on the back of the FSP200 splicer Splice on Connector...

Страница 17: ...Bright key for LCD Down key Dark key for LCD Start Stop heating protection Re calibrates arc power Resets the motor position Starts splicing work Switches between X Y and X Y views Appendixes Refer to...

Страница 18: ...alibration works in this splice mode 2 AUTO SM For splicing standard single mode fiber ITU T G652 The MFD is 9 to 10 m at wavelength of 1310 nm Automatic arc calibration works in this splice mode 3 AU...

Страница 19: ...MM1 For splicing multi mode fiber ITU T G651 Core diameter 50 0 to 62 5 m User can edit all parameters of this splice mode such as prefuse power prefuse time arc power arc time align proof test etc T...

Страница 20: ...e splice mode Then press OK to confirm Note 1 AUTO SM NZ DS MM mode is recommended for splicing in most cases In this mode the splicer automatically adjusts splice parameters according to the fiber ty...

Страница 21: ...mit in degrees Cleaning Arc Set or disable the duration of the cleaning arc Gap Increase the gap if the fibers are soft and melt too easily Decrease the gap if the fibers are hard to melt Gap Set Set...

Страница 22: ...parameters The user will have to perform careful experiments with their individual fibers to obtain optimum results Heater Mode Menu H Mode There are 20 user programmable heating modes Select the one...

Страница 23: ...In Select Heater Mode use the right arrow key to enter the Edit Heater Mode menu Edit Mode for Heater Settings Sleeve Type Enter the protection sleeve name Mode Title1 Enter the heater mode setting n...

Страница 24: ...p into the hole of the electrode polisher and gently rotate the electrode 4 Wipe the electrodes with 99 pure IPA Do not touch the electrode surface with your fingers Now is a good time to clean the ob...

Страница 25: ...he axial offset limit between the two fibers is violated Auto Fiber Forward Enabling allows the fusion splicer to advance the fibers towards each other upon closure of the windshield Realign after pau...

Страница 26: ...mation at the splice This case often results in lower loss than case c Data Save The FSP200 stores up to 5000 splicing results Splice Memory The Splice Memory function allows the user to display expor...

Страница 27: ...ck operation LCD Auto Turn Over Enable or disable the splicer for the LCD to display the splice screens when the LCD screen is tilted to a different axis Auto Heat Switch When enabled the heater will...

Страница 28: ...When the password function is enabled select Set Password Select characters add spaces delete characters or confirm The password max length is 8 and it can be uppercase letters lowercase letters numb...

Страница 29: ...Modes Adjustable 0 240 seconds Tube Heating Time Typical 18s 4 Attenuator Mode 0 1 to 15 dB Electrode Life 5000 Splices Display 3 5 Color Turn Over LCD Connectivity USB Operating Conditions Pressure...

Страница 30: ...ty Check if fiber cleaver is clean and in good condition Prefuse power too low or prefuse time too short Increase Prefuse Power and or Prefuse Time MFD mismatch Arc power too low Increase Arc Power an...

Страница 31: ...or Overlap Note A vertical line sometimes appears at the spice point when MM fibers or dissimilar fibers different diameters are spliced This does not affect splice quality such as splice loss or ten...

Страница 32: ...e MM fiber Set Focus to Edge to splice indistinct core fibers i e MM fiber To splice distinct core fibers enter Auto or the correct focus value Left Right fiber X Y set error The fiber is not set cor...

Страница 33: ...e arc calibration Do arc calibration Electrodes are oxidized Clean electrodes or replace with a new pair Lenses are dirty Clean lenses FIBER_PUSH_ERR Fiber is not in V groove Replace fiber and check i...

Страница 34: ...poor fiber movement during fiber adjusting Clean them periodically Dust or dirt is on the lens or mirror If dust or dirt exists clean the lenses or mirrors Bad electrode condition Replace the electro...

Страница 35: ...om the V groove with a clean dry lint free cotton swab V grooves Cleaved Fiber Figure 1 Figure 2 If the contaminants in the V groove cannot be removed with an alcohol impregnated lint free cotton swab...

Страница 36: ...lean and free of streaks or smudges Turn on the power and make sure no smudges or streaks are visible on the monitor screen Press X Y to change the screen and check the state of the lens surface on bo...

Страница 37: ...daily Refer to Figure 4 If the circular blade or clamp pads of the fiber cleaver become contaminated the cleaving quality could degrade This may lead to fiber surface or end face contamination result...

Страница 38: ...iber type has a pre programmed splicing profile in the FSP200 Use this profile for splicing 4 If there is not an exact matching splice profile use the AUTO mode splicing profile 5 Splice a fiber pigta...

Страница 39: ...icer Make sure to butt the 900 m buffer up to the edge of the fiber adapter This will ensure that the mini splice sleeve will adhere to both sides of the 900 m buffer Installation 1 Remove the factory...

Страница 40: ...urer s instructions 6 Once the fusion splicing cycle is completed remove the connector from the splicer and slide the splice protection sleeve up to cover the splice Make sure that the splice protecto...

Страница 41: ...ear excepting normal wear and abuse For all Test instrument repairs you must first request a Return Authorization Number by contacting our Customer Service department at toll free in the US and Canada...