Specifications
Test Signal Output: 1/2 sine
•
Amplitude (into 75 ohm):
•
6 ns pulse: 5 V
–
12 ns pulse: 6 V
–
Pulse Widths: 6 and 12 ns
•
Output Impedance: 75 ohm
–
Input Protection: 200 VAC + peak DC to a maximum of 440 Hz,
•
30 second duration
Display Ranges: Eight automatic display ranges
•
Gain: 0 to 63 dB
•
Filter: High pass, cutoff frequency 150 kHz, plus averaging
•
Distance Accuracy:
•
0 to 200 ft: ±2 ft
–
Beyond 200 ft: 1% + zero offset
–
Display:
•
Resolution: 520 x 200 pixels
–
Size: 5.25 inches
–
Type: High contrast LCD
–
Backlight: Operator switchable
–
Distance Measurements: Meters, feet, nanoseconds
•
Auto Shutoff Time: Operator selectable, 5 to 30 minutes
•
Temperature Range:
•
Operating: 0 °C to +45 °C (+32 °F to +113 °F)
–
Non-operating: -20 °C to +60 °C (-4 °F to +140 °F)
–
Humidity:
•
Operating: 95% RH, noncondensing at +30 °C to +40 °C
–
(+86 °F to +104 °F)
Field Usage: Shock, splash, and dust resistant
•
EMI Emissions: FCC Part 15, Subpart B, Class A
•