915CL Cleaver
Tempo Communications Inc.
1390 Aspen Way • Vista, CA 92081 USA • 800-642-2155
3
Converting the 915CL to a Fixed Clamp Cleaver
Place the fixed clamp mechanism into the 915CL and secure with the screw
provided.
The 900 micron and 250 micron fiber adapters can be permanently left in the
915FS fusion splicer. If desired one M2X5 screws can be used to secure each
fiber adapter into the fiber adapter mounting area of the 915FS.
Fixed Clamp
Mounting Screw
Blade Replacement
1. Lay down cleaver with scale numbers on blade facing up.
2. Remove blade locking screw.
3. Remove old blade and replace with new blade. Do not touch blade (very
sharp!) Use tweezers to remove old blade and insert new blade.
Normal Use and Maintenance
(con’t)
4. Lock new blade at position “1”.
5. Lay 0.7 mm pencil lead across both pressure pads.
0.7 mm
Pencil
Lead
6. Move slider back and forth and check if blade touches pencil lead.
• If blade touches pencil lead: Perform a cleave and check cleave angle
on 915FS.
If cleave is not good: Check if blade is damaged or dirty at
position “1”.
• If blade drags pencil lead all the way across: Go to “Blade Height
Adjustment”.
• If blade does not touch pencil lead: Rotate pencil lead ≈180°
and try again.
If not sure: Perform a cleave and check cleave angle on 915FS.
If cleave is not good: Go to “Blade Height Adjustment”.