MAINTENANCE PROCEDURES

Although Tempest electric 

Power Blowers

TM

 are designed to 

eliminate most maintenance issues, it is imperative that the 

blowers be inspected before startup on each use.  Please review the 

following list before using this product.  

MAINTENANCE SCHEDULE

EVERY USE 

•  INSPECT BLOWER FOR DAMAGE AND FIX IF 

ANY

•  TIGHTEN/REPLACE ANY LOOSE OR MISSING 

PARTS

EVERY MONTH OR 10 HOURS

•  INSPECT & CLEAN SHROUD & GRILLES

IMPORTANT: Always operate the blower in an area free 

of debris which may be pulled into the unit’s blades. If you 

suspect the fan’s blade may have contacted a hard object, 

thorough inspection of the blade assembly should be 

conducted immediately to ensure safety. You may contact 

Tempest Technology Corp. in order to find out how to 

properly inspect the blade assembly.

POWER BLOWER

TM 

TROUBLESHOOTING 

Various factors can contribute to or be the sole cause of problems 

for electric power blowers. This section will identify some of these 

problems and provide solutions to correct them. 

BLOWER MOVEMENT OR “WALKING”

•  Adjust the rubber footpads on the back of the blower by 

turning them either in or out.  

•  Adjust the side that is walking. This will help to evenly 

distribute the weight of the blower to all four points of the 

frame.

•  Most blowers will walk if not running at full speed, make sure 

the blower is running at full speed.

•  Ensure the blower is sitting flat and not on small rocks or 

other objects.

•  If blower is still walking, contact Tempest at 800.346.2143 or 

[email protected].

SINGLE SPEED

BLOWER FAILS TO START

•  Make sure the unit is connected to the power source.

•  Thoroughly check the power cord. If the cord shows any signs 

of serious wear it may need to be replaced before running 

properly.

•  Many blowers are equipped with an “automatic reset.” This 

reset will kill power to the blower when the unit is at risk of 

overheating. Let the blower cool and attempt to start it again.

•  There may be damage to the internal wiring. Have a qualified 

technician or electronics specialist examine the blower 

circuitry and wiring and make any necessary repairs. 

•  If your Tempest Single Speed blower is not running after 

pursuing the steps mentioned above, please contact us at 

800.346.2143 or [email protected].

VSG & VSR

IF THE “ON” AND THE “STOP” OR “STATUS” LEDS DO 

NOT LIGHT UP

•  Make sure the unit is connected to the power source.

•  Confirm that adequate power is being supplied to blower. If 

power supply is adequate, 

DISCONNECT BLOWER FROM 

POWER SOURCE

 and check for loose or faulty wiring on 

blower electrical system and have a qualified professional 

perform repairs if needed.

•  Connect blower to power source and attempt restarting. If 

blower still does not run, contact Tempest at 800.346.2143 or 

[email protected].

BLOWER SURGES WHEN RUNNING ON GENERATOR:

•  Check that the generator meets the proper voltage output to 

operate the blower.  

•  If blower is still surging, contact Tempest at 800.346.2143 or 

[email protected].

Содержание Power Blower SS Series

Страница 1: ...OWNER S MANUAL Power BlowersTM Cone Air Flow CAF Electric Driven VSR Series VSG Series SS Series Incl BASIC 0216_01A...

Страница 2: ...559 277 7577 f 559 277 7579 response tempest us com www tempest us com TABLE OF CONTENTS ABOUT TEMPEST 2 SAFETY GUIDE 3 GENERAL INFORMATION 3 POWER BLOWERTM DATA 4 POWER BLOWERTM INFORMATION 5 OPERATI...

Страница 3: ...ur Tempest Power BlowerTM 9 Only a qualified technician should perform repairs or maintenance on electric components 10 Never operate your Tempest Power BlowerTM with electric components exposed 11 Ne...

Страница 4: ...T MECHANISM GRILLE VIBRATION DAMPENERS WHEELS NON BASIC SS SPECIFICATIONS SS BASIC SPECIFICATIONS VSG SPECIFICATIONS VSR SPECIFICATIONS Model No Part No Size HP CFM Dimensions WxDxH Weight VS 16 R 2 0...

Страница 5: ...roperly and safely Tempest offers access to a complete line of training materials which cover many applications for this powerful ventilation technique For more information visit www tempest us com ww...

Страница 6: ...sition is the run location 4 Adjust the rheostat knob to the desired speed load STOPPING 1 Stop unit before unplugging from power source Make sure toggle is set to STOP NOTE VSR VSG GFCI systems are s...

Страница 7: ...ing flat and not on small rocks or other objects If blower is still walking contact Tempest at 800 346 2143 or response tempest us com SINGLE SPEED BLOWER FAILS TO START Make sure the unit is connecte...

Страница 8: ...719K 600 720K 600 721K 600 722K 14 LEG ASSEMBLY LEFT DARK GREY 610 1001K 610 1020K 610 1020K 610 1020K 15 LEG ASSEMBLY RIGHT DARK GREY 610 1002K 610 1021K 610 1021K 610 1021K 16 FRAME DARK GREY 610 1...

Страница 9: ...F 7X1 50 OFFSET 240 001 13 HANDLE RECEIEVER ASSY 18 21 BASIC 610 1659 14 PULL UP HANDLE FOR BASIC 600 286K 15 BASIC WHEEL MOUNT LEFT 610 1657 16 BASIC WHEEL MOUNT RIGHT 610 1658 denotes item includes...

Страница 10: ...K 600 716K 600 717K 600 718K 13 WIN STEP YELLOW 600 719K 600 720K 600 721K 600 722K 600 719K 600 720K 600 721K 600 722K 14 LEG ASSEMBLY LEFT DARK GREY 610 1001K 610 1020K 610 1020K 610 1020K 610 1001K...

Страница 11: ...11 NOTES...

Страница 12: ...ditions and Tempest will replace any defective power blower part except the engine or motor and drive if returned during the applicable warranty period for the time frame indicated below Fire ghting I...

Отзывы: