TemperZone SAT-1 Скачать руководство пользователя страница 8

Page 8 

To cancel the key lock, hold down  

TIME

 and 

M O D E

 buttons for 3 seconds, key 

lock symbol

 will no longer be displayed.  

Bypass 

This  feature  provides  a  quick  ‘on  demand’  alternative  to  the  ‘pre-programmed’ 
type  of  use.  Bypass  operation  permits  the  user  to  start  the  air  conditioner 

immediately, bypassing the 

 button and any programmed session times. 

Bypass is initiated by, 

a)  Hold  down 

 or 

 button  for  3  seconds, 

 will  be  shown  at  the 

temperature display area. Letter “H” indicates hour setting.  

b)  Press 

 or 

 to set the bypass timer setting anywhere from 0  to 9 hours. 

c)  Press 

CANCEL

 button will cancel the bypass timer setting. 

d)  System will exit from bypass setting 3 seconds after last key press. 
If Bypass timer is set, the display will alternate between temperature and number 
of countdown hours left, e.g. 8H and the room temperature. Upon Bypass timer 
countdown reaching zero: 
a)  If the On or Off timer settings are nil, system will switch off 
b)  If there is On or Off timer available, the unit will continue to operate if the time 

span  of  the  On  or  Off  timer  allows  it  to  be  on.  At  an  undefined  region  or  off 
time span, the unit will switch off. 

To  terminate  the  bypass  timer  before  chosen  time  has  finished,  press 

 

button to cancel the setting and turn off the air conditioner. 

Buzzer 

Buzzer beeps in response to a valid button press or wireless signal reception. It 
beeps  twice  when  the  system  is  turned  on,  otherwise  beeps  once  to  all  other 
valid acknowledgements. 

Backlight 

Backlight colour changes according to the operating mode setting. 

Operating Mode  Backlight Colour 
Cool 

Blue 

Fan 

Yellow 

Dry 

Pink 

Heat 

Reddish orange 

Auto 

Light violet 

a)  The colour changes to red whenever there is system fault. Whenever the fault 

is cleared, backlight colour will return to original.  

b)  If the unit is on, backlight will turn off 30 seconds after the last button press.  
c)  If  the  unit  is  off,  any  button  press  will  turn  on  the  backlight  and  the  screen 

display.  The  backlight  will  turn  off  10  seconds  after  last  button  press.  Once 
the  backlight  is  turned  on,  setting  can  be  done  the  same  way  as  when  the 
system is on. 

Содержание SAT-1

Страница 1: ...SAT SAT SAT SAT 1 Thermostat 1 Thermostat 1 Thermostat 1 Thermostat USER S OPERATING INSTRUCTIONS AUTO HEATER SUNMON TUE WED THU FRI SAT OFF ON ERR UNIT HEAT COOL FAN DRY SLEEP AUTO SWING ZONE...

Страница 2: ...CONTENTS Page Introduction 3 Features Summary 3 Display 4 Operation 5 Remote Control option 9 Error Code Display 10 Troubleshooting 11 Contact for Service back page...

Страница 3: ...range from 16 C to 30 C Room temperature display Real time clock 7 days programmable Start Stop timer that programs the unit to two start stop sessions per day Bypass function enables user to bypass t...

Страница 4: ...on Swing button Or used in weekly on off timer programming to select day of week To select day of week Sunday to Saturday Day button Room temperature setting button Press again to stop operation Press...

Страница 5: ...the air conditioner cools the room until it reaches the set temperature Dry If the atmosphere in the room is very humid or damp use this mode to both reduce the humidity and cool until the room is nea...

Страница 6: ...to select session 1 P1 or session 2 P2 The selected session is indicated on the temperature display area as P1 or P2 c Press DAY button to change the set day of the on or off timer d If the selected t...

Страница 7: ...ith the cool mode set pressing the SLEEP button gradually raises the set temperature by 2 degrees to compensate for a person s lower metabolism when sleeping In Winter with the heat mode set pressing...

Страница 8: ...is On or Off timer available the unit will continue to operate if the time span of the On or Off timer allows it to be on At an undefined region or off time span the unit will switch off To terminate...

Страница 9: ...Fan Heat Auto Adjust Set Temperature Press down or up button to decrease or increase the desired room temperature Note A temperature can not be set in Fan mode Clock Press down or up button for 2 sec...

Страница 10: ...board AD3 Room sensor 2 failure 2 Main board AD4 Room sensor 3 failure 3 Main board AD5 Room sensor 4 failure 4 Main board AD6 1 indoor coil sensor failure 5 Main board AD1 1 outdoor coil sensor fail...

Страница 11: ...set temperature may have been set too high or too low If the set temperature appears okay call for service Timer is Not Correctly Triggered Check the clock is set to the right time day light saving an...

Страница 12: ...ries in the remote control aren t flat 2 The infra red remote control must be pointed directly at the SAT 1 wall thermostat plaque in order for its signal to be received 3 If there is no light or beep...

Страница 13: ...AND Temperzone Ltd Phone 0 9 279 5250 Fax 0 9 275 5637 SYDNEY Temperzone Australia Pty Ltd Phone 02 8822 5700 Fax 02 8822 5711 SINGAPORE Phone SNG 6733 4292 Fax SNG 6235 7180 Your local service agent...