background image

KLD2

 

 

 

 

 

 

 

 

 

 

 

 

 

Instruction

 

Welcome to use KLD2 Infrared LED Sensor Lamp! 

The product is an energy-saving automatic sensor lamp, adopting integrated circuit and precise 

detecting components. It gathers automatism, convenience, safety, saving-energy and practical 

functions. Its performance is stable. It can identify day and night. The lamp can turn on when one 

enters detection field and can turn off automatically when one leaves detection field.

 

SPECIFICATION: 

Power Source: 220-240V/AC                                      Detection Range: 240

°

 

Power Frequency: 50/60Hz                                          Detection Distance: 5-10m

 

Ambient Light: <3-2000LUX (adjustable)                  Working Temperature: -20~+40

 

Time Delay: Min.10sec

±

3sec                                    Working Humidity: <93%RH 

                      Max.15min

±

2min                                    Installation Height: 1.8-2.5m 

Rated Load: 30W (2200LM)                                        Detection Moving Speed: 0.6-1.5m/s 

Additional switching capacity: 500W

                                     

IP Class: IP65 

FUNCTION: 

 

Can identify day and night: The consumer can adjust working state in different ambient light. 

It can work in the daytime and at night when it is adjusted on the “sun” position (max). It can 
work in the ambient light less than 3LUX when it is adjusted on the “3” position (min). As for 

the adjustment pattern, please refer to the testing pattern.   

 

SENS adjustable: It can be adjusted according to using location. The detection distance of 

low sensitivity could be only 5m and high sensitivity could be 10m which fits for large room. 

 

Time-Delay is added continually: When it receives the second induction signals within the 

first induction, it will restart to time from the moment. 

 

Adjustable Time Delay: the length of time delay could be set according to the customers’ 

requirement, the minimum time of this item is 10sec ± 3sec, the maximum is 15min±2min. 

 

 

 

Good sensitivity                                                                            Poor sensitivity

 

INSTALLATION: 

  Switch off the power. 

  Screw off the nail on the bottom of sensor lamp and 

unload  the  bottom.  Open  the  wire  hole  in  the 

bottom and pass the wire through the hole. 

  Fix the bottom on the selected position with the inflated screw. 

  Connect  the  power  wire  into  connection-wire  column  according  to  the  connection-wire 

diagram. 

 

Fix back the sensor lamp on the bottom. Switch on the power and then you can test it. 

 

It not only can install on the wall directly but  also can install  in the outer corner with the 

help of the widget (refer to photograph below): 

 

 

 

Flat mounted

     

Outer corner mounted

 

 

The  LED can  tilt  up/down,  turn  left/right  according  to 

the customers

’ requirement as the right drawing: 

Содержание KLD2

Страница 1: ...ental inferior a 3LUX cuando se ajusta en la posici n 3 m n En cuanto al patr n de ajuste consulte el test de prueba SENS ajustable se puede ajustar seg n la ubicaci n de uso La distancia de detecci n...

Страница 2: ...l m nimo 3 Si la luz ambiental es m s de 3LUX la l mpara no deber a funcionar Si cubre la ventana de detecci n con objetos opacos toalla etc la l mpara funcionar En condiciones sin se al de detecci n...

Страница 3: ...pci n de las se ales B Compruebe si la temperatura ambiente es demasiado alta C Compruebe si la fuente de la se al de inducci n est en el campo de detecci n D Compruebe si la altura de instalaci n cor...

Страница 4: ...the adjustment pattern please refer to the testing pattern SENS adjustable It can be adjusted according to using location The detection distance of low sensitivity could be only 5m and high sensitivi...

Страница 5: ...ws to affect detection Avoid installing it near air temperature alteration zones such as air condition central heating etc Considering your safety please do not open the cover when you find the hitch...

Страница 6: ...eil max Il peut fonctionner avec une lumi re ambiante inf rieure 3 LUX lorsqu il est r gl sur la position 3 min En ce qui concerne le mod le d ajustement veuillez vous r f rer au test d essai SENS r g...

Страница 7: ...lampe ne devrait pas fonctionner Si vous couvrez la fen tre de d tection avec des objets opaques serviette etc la lampe fonctionnera Dans des conditions sans signal de d tection la lampe doit cesser...

Страница 8: ...la r ception des signaux B V rifiez si la temp rature ambiante est trop lev e C V rifiez si la source du signal d induction se trouve dans le champ de d tection D V rifiez si la hauteur d installation...

Страница 9: ...ar com luz ambiente inferior a 3LUX quando definido para a posi o 3 min Quanto ao padr o de ajuste consulte o teste de teste SENS Ajust vel Pode ser ajustado de acordo com o local de uso A dist ncia d...

Страница 10: ...mbiente for superior a 3LUX a l mpada n o deve funcionar Se voc cobrir a janela de detec o com objetos opacos toalha etc a l mpada funcionar Em condi es sem sinal de detec o a l mpada deve parar de fu...

Страница 11: ...tor que afete a recep o dos sinais B Verifique se a temperatura ambiente est muito alta C Verifique se a fonte do sinal de indu o est no campo de detec o D Verifique se a altura de instala o correspon...

Отзывы: