Programming
● Set dip switch 8 to the ON position (All the other switches have no effect)
● The service blue LED will light up and the brightness of the indicator LEDs will be lowered
● Press and release button PL1 to change the sequence until the desired one is obtained
● Press and release the PL2 button to vary the color until the desired color is obtained
● Press and HOLD the PL1 button until the blue service LED flashes quickly, then release button PL1: the program-
ming has been stored. If you don't do this, the programming will NOT stored
● Return dip switch 8 to the OFF position
● The blue service LED will flash for about 10 seconds to allow clockwise coupling of the cover, then the indicator
LEDs, if activated, will return to full brightness
When turned on, the indicator repeats the last programming that was stored in the internal Flash memory. It is
possible to choose both a flashing sequence and one of the 7 available colors.
The PL1 button allows the choice of the flashing sequence.
The PL2 button allows the choice of one of the 7 colors: White, Green, Red, Blue, Yellow, Light blue, Pink.
BLUE LED
Off
ON
1
8
+12-24V
- GND
A
B
External
contact or A-
B jumper
Ways of using
● Device powered on JEX1 terminals with activation from external contact on JEX2
● Device powered with 12-24V only upon activation, make a jumper between A-B of JEX2