2.  TYPICAL OPERATING DIAGRAM 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

When  the  visitor  presses  the  button,  AA-15IP  generates  a  SIP  call  to  an  internal  number,  putting  the  visitor  in 
communication  with  the  operator,  who  has the  possibility to operate  the  gate opening  relay  with  a code  from  the 
phone. In any case, the internal doorphone station remains operational since AA-15IP works in parallel. 
 
The  contacts  of  Relay  2  can  also  be  brought  to  the  internal  station  to  allow  the  opening  of  a  second  gate  or  to 
switch on any lights.  
 
Both  relays  can  be  activated  not  only  following  the  call  from  the  doorphone  but  also  by  calling  AA-15IP  to  the 
assigned number/IP address, wait for the answer and activate them with codes from the telephone keypad. 
 
In  the  presence  of  the  IP-PBX,  calls  from  the  doorphone  can  be  routed  to  external  phone  numbers,  including 
mobile.   
 

IMPORTANT NOTE: the quality of the audio received and transmitted is strictly dependent on the quality of 

the intercom system, the device does NOT correct any disturbances or low audio quality of the existing 

intercom system but transfers the audio exactly as it receives it. 

 
 
 
 
 
 
 

3.  PACKING LIST 

 
The system consists of the parts included in the following list: 

 

  1 AA-15 interface module 

  1 CD with system documentation 

  1 quick guide 

  1 ABS bracket for wall mo 2 screws 

  1 RJ45 1.5mt LAN cable 

  1 RJ45 cable for TAP socket 

 
NOTE: an optional kit is available for fixing the AA-15 module on a DIN bar, code AA-697/DIN. 
 
 
 
 
 
 

RELAY 1 

 

Visitor 

 

PoE Switch 

 

8 signal wires 
from internal 
station 

 

IP SIP Phone 

 

AA-15IP

 

 

 

PSTN 

UTP Cable 

cat. 5/6 

 

UTP Cable 

cat. 5/6 

 

Alarm  

input 

 

Doorphone 
central unit 

 

  

IP-PBX 

SIP 

SERVER 

Operator and internal  

network telephones

 

 
 

RELAY 2 

auxiliary 

 

Existing 
external 
Doorphone 

 

Existing 

internal station 

 

Содержание AA-15IP

Страница 1: ...e not supplied 2 The device has been carefully manufactured and tested In any case the product is not recommended for use in situations in which incorrect operating may result in damage to persons and or property 3 We recommend that you carefully read all this manual before starting to use the device 4 Do not expose the device to sunlight and protect it from sources of heat dust humidity and chemi...

Страница 2: ...sed out wheeled bin symbol below indicates that this electronic equipment is intended to be disposed in a separate collection and not in an unsorted municipal waste in order to provide for the treatment of WEEE Waste Electrical and Electronic Equipment using best available recovery and recycling techniques Specific treatment for WEEE is indispensable in order to avoid the dispersion of pollutants ...

Страница 3: ... 6 Products powered via PoE Power over Ethernet may only be connected with cables coming from the internal network company inside the building are not allowed connections LAN cables coming from outside the building 7 Use for this device only and exclusively original spare parts and consumables supplied by Tema Telecomunicazioni The company is not responsible for damage caused by the use of materia...

Страница 4: ...8 7 8 DAY NIGHT INTERVAL COMMAND CODES FOR THE OPERATOR 18 7 9 RELAY AND ALARM SETTINGS 19 7 10 ACQUISITION OF INPUT ALARM CONTACTS 20 7 11 CALL BUTTONS 21 7 12 MESSAGES MANAGEMENT 21 8 MAINTENANCE 22 8 1 SYSTEM 22 8 2 LOGIN CREDENTIALS 23 8 3 DIAGNOSTIC LOG 23 9 APPENDIXES 24 9 1 USE OF THE AUDACITY SOFTWARE FOR AUDIO FILES RECORDING 24 9 2 CABLING OF A UTP RJ45 NETWORK CABLE ACCORDING TO THE STA...

Страница 5: ... intercom of the single user AA 15IP integrates a PoE power supply and can therefore be powered on the same cat5 6 LAN cable if coming from a PoE switch Alternatively an input for external 230Vac power supply is available Optional The dimensions 76 5x62xH32 5mm connectors excluded they are extremely compact and the system can be fixed to the wall with the included bracket or on a DIN bar with a sp...

Страница 6: ...sence of the IP PBX calls from the doorphone can be routed to external phone numbers including mobile IMPORTANT NOTE the quality of the audio received and transmitted is strictly dependent on the quality of the intercom system the device does NOT correct any disturbances or low audio quality of the existing intercom system but transfers the audio exactly as it receives it 3 PACKING LIST The system...

Страница 7: ...available input contact VoIP IP LAN section Integration with the local LAN LAN 100 BaseT Ethernet port with RJ45 connector VoIP connection with SIP protocol both in SIP Proxy Server mode Registration on IP PBX and Peer to Peer possibility of PoE Power over Ethernet power supply 5 TECHNICAL FEATURES Generals Insertion terminals for wiring Possibility of using cables up to 1 5mm2 or AWG16 Number of ...

Страница 8: ...larity Auxiliary voltage output RJ45 PoE LAN Cable Auxiliary relay 2 output UTP cable from TAP 8 7 6 5 4 3 2 1 BR WH GR WH BL WH OR WH BR BL GR OR MIC SP LOCK OPENING BUZZER TO THE DOORPHONE Indoor station or central power supply TAP The terminations of the UTP cable coming from the RJ45 socket called TAP must be connected to the terminals of the internal station or to the respective signals of th...

Страница 9: ...nternal electronics and converted into VoIP SIP protocols IMPORTANT NOTE the quality of the audio received and transmitted is strictly dependent on the quality of the intercom system the device does NOT correct any disturbances or low audio quality of the existing intercom system but transfers the audio exactly as it receives it Devices powered via PoE Power over Ethernet may only be connected wit...

Страница 10: ...owing a code dialed on the internal telephone keypad The device works transparently while maintaining the functionality of the indoor station which can continue to be used normally A second relay is available for other functions An alarm input is available which if closed makes a phone call and sends a message NOTE see the wiring diagrams of other brands and models of interphones in the appendices...

Страница 11: ... connect to the web interface of AD635 it is necessary that in the IP addresses configuration of your PC is present the subnet 192 168 0 x where x is any number between 1 and 254 and different from 10 See below how to configure your PC to reach the correct subnet The shown procedure applies to Windows operating systems Open the Windows Control Panel and set the field View by Category Large Icons o...

Страница 12: ...member the current TCP IP configuration of your computer for any subsequent restore of the correct parameters Click Use the following IP address and type in the appropriate field the following IP address 192 168 0 11 instead of 11 used in the example it is possible to enter any number between 1 and 254 but excluding the 10 which is the default address of the system to be programmed In the Subnet M...

Страница 13: ...ossbile to change the administrative password for the maximum safety of your device Once logged in it is possbile to change the administrative password for the maximum safety of your device see par 8 2 The use is very simple and intuitive the menu for selecting the functions to be programmed is always visible on the left while the configuration mask active at that time is shown on the right Each c...

Страница 14: ...reboot the system and if necessary change the network segment of your computer so that it can connect to the new address IP address specify the IP address you want to assign to AA 15 Subnet mask indicate the subnet mask to be assigned to AA 15 Default gateway indicate the gateway that can enable AA 15 to access to internet Primary and secondary DNS server indicate the addresses of two DNS servers ...

Страница 15: ...e 5060 but some stations use a different port Domain enter the domain to which register the system Outbound proxy some PBXs require that the extension number to call is followed by the proxy address In most cases this field can be left empty Local SIP port generally the 5060 port is used but it is possible to specify a different number i e for particular routing tables User password credentials fo...

Страница 16: ...es an incoming call if this field is programmed the audio will not be connected until the user will enter the right connection code Monitoring code as in the previous case for incoming calls the audio is not connected until the code is entered but in this case only the audio from microphone is connected a sort of monitor function it is possible to hear the audio near the doorphone Calling speaker ...

Страница 17: ...wer via DTMF type the code corresponding to the selected mode The codes must consist of 2 characters Time bands in the case of automatic operation it is possible to enter up to 5 bands per day If a field is left blank it is unused and the previous corresponding band will be used Time zone time zone of the location where the installation is made 1 for Italy Latitude Longitude Geographical decimal c...

Страница 18: ...witch to each mode based on a time schedule When the visitor presses the button a call is made to one of the PBX extensions associated with the pressed button The numbers that will be called may differ depending on the operating mode in which the system is located Day Night Interval mode see par 7 6 In the case of expansion with a keyboard this allows the desired number to be dialed directly or to...

Страница 19: ... system based on the current time and location of the installation the exact time should be obtained from the internet PHONE activation relay activation code to dial from the extension of the PBX 2 characters required Activation time activation time of the relay Activation delay for relay 2 after how many seconds you have to turn with respect to the activation of relay 1 if set in after Relay 1 Cl...

Страница 20: ...essage to be reproduced during the call A neutral message Alarm1 is reproduced as standard but the text can be customized It is possible to associate a phone number or an IP address that will be called during the alarm phase The closure of an external contact triggers the signaling sequence but it is also possible to reverse this logic so the signaling can occur following the opening of the contac...

Страница 21: ...to 2 numbers registered in the IP PBX to contact P2P Peer to Peer call in the absence of an IP PBX it is possible to insert in the windows the IP address of the terminal to be called a P2P call will therefore be established when Key 1 is pressed NOTE it should be noted that the AA 15 system works in a transparent way and does not affect the functionality of the intercom system this means that the ...

Страница 22: ...urrent settings to restore them in case of a programming error or device replacement Reset to factory settings all settings are lost and reset to factory defaults You are prompted to confirm the operation Device reboot reboot as if it were taken away and put back power Useful in case you have not physically present in front of the device and it needs to restart it You are prompted to confirm the o...

Страница 23: ...rd should be introduced twice for confirmation If for any reason your password was forgotten it is possible to reset it to the default closing a jumper inside the device see par 0 8 3 Diagnostic log To identify small configuration problems it is possible to activate a diagnostic summary on the activity of the two VoIP channels of the device Simply connect via TCP port 9991 with Telnet or a termina...

Страница 24: ... the previous recording simply select the audio track crawl from start to finish press the Delete button and repeat the recording With this procedure it is also possible to delete small parts of silence or sound inside the track 3 To save the recording click on File Export Audio give a name and select in the WAV Microsoft 16 bit PCM format drop down list The saved file is ready to be used on all d...

Страница 25: ...ires some additional millimeter Hold with one hand the wires and with the other pull the smoothing sheath Straighten the wires previously individually pair twisted Compose the color sequence following the pattern Level the length of the cables into place Insert the tightened wires into RJ45 connector holding them between your fingers until they are channeled into the guides inside the connector it...

Страница 26: ... Page 26 of 32 9 3 Connection with URMET intercom 8 7 6 5 4 3 2 1 UTP cable from TAP Switch PoE IP PBX SIP SERVER IP SIP Phone Alarm contact input Second auxiliary relay 12Vdc Vac Input if PoE not available 12Vdc Max 200mA Output POWER SUPPLY DOOR OPENER AMPLIFIED DOOR STATION ...

Страница 27: ...Interface AA 15IP MAS AA15 REV00EN Page 27 of 32 9 4 Connection with URMET mod 1130 intercom 8 7 6 5 4 3 2 1 UTP cable from TAP INTERCOMS TO SUBSEQUENT INTERCOMS PUSH BUTTON PANEL AND EXTERNAL UNIT MAINS POWER SUPPLY LOCK OPENING ELECTRIC LOCK ...

Страница 28: ...OMUNICAZIONI SRL VoIP Doorphone Interface AA 15IP MAS AA15 REV00EN Page 28 of 32 9 5 Connection with BPT intercom 1 2 3 4 5 6 7 8 UTP cable from TAP AMPLIFIED DOOR STATION POWER SUPPLY DOORBELL BUTTON DOOR OPENER ...

Страница 29: ...TELECOMUNICAZIONI SRL VoIP Doorphone Interface AA 15IP MAS AA15 REV00EN Page 29 of 32 9 6 Connection with TERRANEO intercom 1 2 3 4 5 6 7 8 UTP cable from TAP POWER SUPPLY AMPLIFIED DOOR STATION DOOR OPENER ...

Страница 30: ...TEMA TELECOMUNICAZIONI SRL VoIP Doorphone Interface AA 15IP MAS AA15 REV00EN Page 30 of 32 9 7 Connection with FARFISA intercom 9 8 Connection with COMELIT intercom ...

Страница 31: ... In any case the internal intercom station remains operational since AA 15IP is transparent and works in parallel I can t get to the place where I have to install AA 15 with a UTP cable can I use a Wi Fi link Yes AA 15 is a normal LAN network terminal in this case you need a client access point with the RJ45 LAN output towards AA 15 and a power supply for example the plug model T7012L or for DIN r...

Страница 32: ...TEMA TELECOMUNICAZIONI SRL VoIP Doorphone Interface AA 15IP MAS AA15 REV00EN Page 32 of 32 NOTES ...

Отзывы: