background image

 

SERIAL PORT CONFIGURATION

 

 

 
 
 
     
 

 
 

VISCA PROTOCOL 

Part1 Camera Return Command 

Ack/Completion Message 

 

Command Packet 

Note 

ACK 

z0 41 FF 

Returned when the command is accepted.   

Completion 

z0 51 FF 

Returned when the command has been executed. 

z = camera 8 

 

Part 2 Camera Control Command 

Command 

Funnation 

Command Packet 

Note 

AddressSet 

Broadcast 

88 30 01 FF 

Address setting 

IF_Clear 

Broadcast 

88 01 00 01 FF 

I/F Clear 

CommandCancel 

 

 

8x 21 FF 

 

 

CAM_Power 

On 

8x 01 04 00 02 FF 

Power ON/OFF 

Off 

8x 01 04 00 03 FF 

CAM_Zoom 

Stop 

8x 01 04 07 00 FF 

 

 

Tele(Standard) 

8x 01 04 07 02 FF 

Wide(Standard) 

8x 01 04 07 03 FF 

Tele(Variable) 

8x 01 04 07 2p FF 

p = 0(low)~7(high) 

Wide(Variable) 

8x 01 04 07 3p FF 

Direct 

8x 01 04 47 0p 0q 0r 0s FF 

pqrs: Zoom Position      (0(wide) 
~0x4000(tele)) 

CAM_Focus 

Stop 

8x 01 04 08 00 FF 

 

 

Far(Standard) 

8x 01 04 08 02 FF   

Near(Standard) 

8x 01 04 08 03 FF 

Parameter 

Value 

Parameter 

Value 

Baud rate 

2400/4800/9600/115200 

Stop Bit 

1bit 

Start Bit 

1 bit 

Check Bit 

None 

Date Bit 

8 bit 

 

 

Error Messages 

 

Command 

Packet 

Note 

Syntax Error 

z0 60 02 FF 

Returned when the command format is different or when a command with 
illegal command parameters is accepted. 

Command Not 
Executable 

z0 61 41 FF   

Returned when a command cannot be executed due to current conditions. 
For example, when commands controlling the focus manually are received 
during auto focus. 

All manuals and user guides at all-guides.com

all-guides.com

Содержание TLC-700-S

Страница 1: ...TLC 700 S HD PTZ Video Camera User Manual Version V1 0 English All manuals and user guides at all guides com a l l g u i d e s c o m...

Страница 2: ...HTS 3 CAMERA SPEC 3 CAMERA INTERFACE 4 CAMERA DIMENSION 4 IR REMOTE CONTROLLER 5 VISCA IN RS232 PORT 7 SERIAL PORT CONFIGURATION 8 VISCA PROTOCOL 8 PELCO D PROTOCOL 15 PELCO P PROTOCOL 16 OSD MENU 17...

Страница 3: ...All manuals and user guides at all guides com...

Страница 4: ...ransportation storage and installation 7 Do not detetch the camera housing and cover For any service please contact authorized technicians 8 RF cable and control cable should be individually shielded...

Страница 5: ...tom of the camera Dial Switch ARM SW 1 SW 2 Instruction 1 OFF OFF Updating mode 2 ON OFF Debugging mode 3 OFF ON Undefined 4 ON ON Working mode Dial Switch IR CODE TYPE SW 3 SW 4 Instruction 1 OFF OFF...

Страница 6: ...a VISCA IN port 10 Multi language menu English Chinese Russian Spanish CAMERA SPEC Video Format 1080P60 50 30 25 1080I60 50 720P60 50 30 25 Or 1080P59 94 50 29 97 25 1080I59 94 50 720P59 94 50 29 97 2...

Страница 7: ...Base 6 Tripod Screw Hole 10 CVBS port 3 IR Receiver Panel 7 Installation Hole 11 HD SDI port 4 Power Indicator Light 8 VISCA IN port 12 DVI I port 5 Power Input 12VDC 14 Power Indicator Light 13 Powe...

Страница 8: ...Once press the IRT key the camera will receive and pass the IR remote control signal to the codec terminal via VISCA IN port SET 1 SET4 ADDRESS SETTING Long press for 3seconds until the key light ON t...

Страница 9: ...et the pan tilt right limit position LMT CLR Clear the limit position BLC OFF BLC ON Close open back light compensation BRIGHT BRIGHT Set image brightness only valid under bright priority exposure mod...

Страница 10: ...3 TXD 4 GND GND 5 RXD 6 A A 7 IR OUT 8 B B VISCA IN Mini DIN Connection Camera VISCA IN Mini DIN 1 DTR 1 DSR 2 DSR 2 DTR 3 TXD 5 RXD 4 GND 4 GND 5 RXD 3 TXD 6 A 6 GND 7 IR OUT 7 NC 8 B 8 NC VISCA IN...

Страница 11: ...e Variable 8x 01 04 07 2p FF p 0 low 7 high Wide Variable 8x 01 04 07 3p FF Direct 8x 01 04 47 0p 0q 0r 0s FF pqrs Zoom Position 0 wide 0x4000 tele CAM_Focus Stop 8x 01 04 08 00 FF Far Standard 8x 01...

Страница 12: ...4 43 00 00 0p 0q FF pq R Gain 0 0xFF CAM_Bgain Reset 8x 01 04 04 00 FF Manual Control of B Gain Up 8x 01 04 04 02 FF Down 8x 01 04 04 03 FF Direct 8x 01 04 44 00 00 0p 0q FF pq B Gain 0 0xFF CAM_AE Fu...

Страница 13: ...00 00 0p 0q FF pq Aperture Gain 0 0x04 CAM_Memory preset Reset 8x 01 04 3F 00 0p FF p Memory Number 0 to 127 Corresponds to 0 to 9 on the Remote Commander Set 8x 01 04 3F 01 0p FF Recall 8x 01 04 3F...

Страница 14: ...01 7D 01 03 00 00 FF IR remote commander receive message via the VISCA communication ON OFF Off 8x 01 7D 01 13 00 00 FF Pan_tiltDrive Up 8x 01 06 01 VV WW 03 01 FF VV Pan speed 0x01 low speed to 0x18...

Страница 15: ...ition CAM_GainPosiInq 8x 09 04 4C FF y0 50 00 00 0p 0q FF pq Gain Position CAM_ BrightPosiInq 8x 09 04 4D FF y0 50 00 00 0p 0q FF pq Bright Position CAM_ExpCompModeInq 8x 09 04 3E FF y0 50 02 FF On y0...

Страница 16: ...ILT ABSOLUTE POSITION VALUE Pan Angle VISCA Value Tilt Angle VISCA Value 170 0xF670 30 0xFE50 135 0xF868 0 0x0000 90 0xFAF0 30 0x01B0 45 0xFD78 60 0x0360 0 0x0000 90 0x510 45 0x0288 90 0x0510 135 0x07...

Страница 17: ...1 15 17 f1 8 3 1 8 2 1 0 Gain 0 0dB Gain 8 16dB 1 2dB 9 18dB 2 4dB 10 20dB 3 6dB 11 22dB 4 8dB 12 24dB 5 10dB 13 26dB 6 12dB 14 28dB 7 14dB ZOOM RATE ZOOM VALUE Optical Zoom Digital Zoom Zoom Rate Va...

Страница 18: ...F Address 0x00 0x20 0x00 0x00 SUM Zoom Out 0xFF Address 0x00 0x40 0x00 0x00 SUM Focus Far 0xFF Address 0x00 0x80 0x00 0x00 SUM Focus Near 0xFF Address 0x01 0x00 0x00 0x00 SUM Set Preset 0xFF Address 0...

Страница 19: ...ress 0x00 0x40 0x00 0x00 0xAF XOR Focus Far 0xA0 Address 0x00 0x80 0x00 0x00 0xAF XOR Focus Near 0xA0 Address 0x01 0x00 0x00 0x00 0xAF XOR Set Preset 0xA0 Address 0x00 0x03 0x00 Preset ID 0xAF XOR Cle...

Страница 20: ...OSD menu Before exiting will show up a window to select whether need to save all settings useLEFT RIGHT key to set As bellow 5 OSD Menu Setting List SYSTEM PROTOCOL VISCA PELCO P PELCO D ADDRESS VISCA...

Страница 21: ...DZOOM Turn on off digital zoom FOCUS Select focus mode QUALITY 2D NR 2D noise reduction 0 5 the bigger value the less noise on image the lower resolution 3D NR 3D noise reduction 0 3 the bigger value...

Страница 22: ...nd SEJIN 4PPM code For customized with other code pls contact us for adding 2 Once the camera power on and finish configuration if set to NEC code can enable the IR transfer function via OSD menu or v...

Страница 23: ...20 All manuals and user guides at all guides com...

Отзывы: