![Telycam TLC-1000-DS Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/telycam/tlc-1000-ds/tlc-1000-ds_user-manual_1085203010.webp)
9
VISCA PROTOCOL
PART 1 CAMERA RETURN COMMAND
Ack/Completion Message
Command Packet
Note
ACK
z0 41 FF
Returned when the command is accepted.
Completion
z0 51 FF
Returned when the command has been executed.
z = camera 8
Error Messages
Command Packet
Note
Syntax Error
z0 60 02 FF
Returned when the command format is different or when a command with
illegal command parameters is accepted
Command
Not
Executable
z0 61 41 FF
Returned when a command cannot be executed due to current conditions. For
example, when commands controlling the focus manually are received during
auto focus.
Part2 CAMERA CONTROL COMMAND
Command
Function
Command Packet
Note
AddressSet
Broadcast
88 30 01 FF
Address setting
IF_Clear
Broadcast
88 01 00 01 FF
I/F Clear
CAM_Power
On
8x 01 04 00 02 FF
Power ON/OFF
Off
8x 01 04 00 03 FF
CAM_Zoom
Stop
8x 01 04 07 00 FF
Tele(Standard)
8x 01 04 07 02 FF
Wide(Standard)
8x 01 04 07 03 FF
Tele(Variable)
8x 01 04 07 2p FF
p = 0(low)~7(high)
Wide(Variable)
8x 01 04 07 3p FF
Direct
8x 01 04 47 0p 0q 0r 0s FF
pqrs: Zoom Position (0(wide)
~0x0080(tele))
CAM_WB
Auto
8x 01 04 35 00 FF
Indoor
8x 01 04 35 01 FF
Outdoor
8x 01 04 35 02 FF
OnePush
8x 01 04 35 03 FF
ATW
8x 01 04 35 04 FF
Manual
8x 01 04 35 05 FF
Outdoor Auto
8x 01 04 35 06 FF
Sodium Lamp
Auto
8x 01 04 35 07 FF
Sodium Auto
8x 01 04 35 08 FF
CAM_RGain
Reset
8x 01 04 03 00 FF
Manual Control of R Gain
Содержание TLC-1000-DS
Страница 1: ...Dual SDI ePTZ Camera User Manual Version V1 0 English ...
Страница 2: ...1 ...
Страница 20: ...19 ...