P

HONECELL

SX3i AMPS

17

U

SER

M

ANUAL

12/08/99

Phonecell Operation – Continued

Important Tones and Alerts

No-Service Tone – 

When cellular service is not available, the receiver emits a

No-Service 

(fast-beeping)

tone instead of the normal 

(steady) 

dial tone. 

ROH (Receiver Off-Hook) Tone – 

If the telephone equipment remains off-hook

(off its cradle)

with no dialing activity for 45 seconds, the receiver emits an ROH

tone for 60 seconds. 

Incoming Call Alert –

If you’re dialing a number and an incoming call occurs,

the receiver will emit an audible ring. To answer the incoming call: 

··

Press the “HOOKFLASH” button once. This will connect the incoming call. 

··

OR hang-up immediately. This will cause the phone to start ringing.

How to Adjust the Volume Level

If the volume level on your phone is too high or too low, you can adjust the levels

using the keypad on your telephone. 

Note: your telephone must be in Tone-

Dial 

(DTMF)

mode to adjust the levels. 

To Increase Audio Level - 

Increase the audio level in steps by pressing:

F

#

*

8

(also known as  

#

*

Up

)

Continue to press  

#

*

8

until the desired level is reached.

To Decrease Audio Level - 

Decrease the audio level in steps by pressing:

F

#

*

3

(also known as  

#

*

Down

)

Continue to press  

#

*

3

until the desired level is reached.

NOTE:

The default setting lets you adjust the audio up to three (3) steps in

either direction 

(Up or Down)

Fax/Data Transmission

Automatic Level Setting (ALS)

When  your 

Phonecell  SX3 

detects  a  fax  or

modem call, it automatically adjusts the Transmit

and  Receive  audio  levels  for  optimum  data

transmission. After  the  fax/data  transmission  is

completed, the Phonecell resets the audio levels

to their previous settings (patent pending).

Fax/Modem Compatibility

Your Phonecell is compatible with all Group 3 facsimile

machines  and  computer  modems.  Depending  upon

the  type  of  modem  used  and  the  cellular  network’s

capability, data transmission rates of 2400 baud and

higher are normally possible.

Содержание Phonecell SX3i AMPS

Страница 1: ...PHONECELL SX3i AMPS FIXED WIRELESS TERMINAL USER MANUAL Total communications freedom at your fingertips voice fax data 12 08 99 Part No 56016602 PHONECELL SX...

Страница 2: ...ation Corporate Headquarters 647 North Lakeview Parkway Vernon Hills Illinois 60061 USA TECHNICAL SUPPORT Tel 847 247 9400 Fax 847 247 0021 E mail mainoffice telular com http www telular com Patents T...

Страница 3: ...ace a Call 16 How to Receive a Call 16 How to End a Call 16 The Hookflash Function 16 Important Tones and Alerts 17 How to Adjust the Volume Level 17 Fax Data Transmission 17 Variable Dial Time Auto S...

Страница 4: ...litter if you plan to 4 connect more than one telephone device Components Needed Tools Materials Needed for Wall Mount Installation Only Qty Description Supplied Not Supplied 1 Drill Drill Bit 4 1 Scr...

Страница 5: ...tep 3 Then return to this step 2 Plug in additional phones Fax and or Modem Step 3 NAM Phone Number Setup pg 9 11 If your Phonecell was not pre programmed for NAM information you need to perform the N...

Страница 6: ...etc to ensure a minimum separation of 16 inches 40 cm between the antenna and the inhabitants In low signal areas the antenna should be mounted on the building s exterior see Fig 2 High gain Yagi ant...

Страница 7: ...he antenna from one location to another until you achieve the best signal strength possible Test the cellular signal strength by checking the LED indicator on the front of your Phonecell Solid RED No...

Страница 8: ...see Step 1 page 6 7 The NAM Phone Number needs to be set up see Step 3 page 9 11 Your cellular phone number has not been activated contact your cel lular service provider Adding More Phones Plug in an...

Страница 9: ...correct you ll hear the programming tone again Step 4 Press 5 _ _ _ _ _ The spaces represent your 1 to 5 digit System Identifier SID which ranges from 0 to 32 767 This information identifies your cell...

Страница 10: ...providers To change the setting you must enter a 1 to 4 digit number in the range of 0 to 1023 For example to set up channel 565 enter 24 565 If you enter the channel incorrectly you ll hear three sho...

Страница 11: ...ing LED indicator will become solid GREEN Phone number setup is complete F F F F F F NAM Phone Number Setup Override Commands PHONECELL SX3i AMPS 11 USER MANUAL 12 08 99 Optional A Key Authentication...

Страница 12: ...these instructions exactly If the wire leads are not connected to the proper terminals the circuit board and or transceiver may be damaged Always observe proper polarity make sure the colored wires ma...

Страница 13: ...nst the compartment wall or guides 9 Once the batteries lay flat replace the battery compartment cover and slide the cover closed until the securing tab pops up Battery Installation is complete 10 Re...

Страница 14: ...lign the mounting holes on the Phonecell with the two wall mounted screws Then mount the Phonecell onto the screws and slide it down ward until the screw heads lock into the mounting holes and the uni...

Страница 15: ...onecell as this could cause the unit to overheat and fail 5b Desktop Tabletop Installation After all connections are made turn your Phonecell SX3 face down and attach the 3 rubber feet to the bottom s...

Страница 16: ...ephone handset your phone is now off hook 2 Listen for dial tone If service is not available a No Service tone is produced Hang up the phone and try again 3 Dial the phone number How to Receive a Call...

Страница 17: ...Note your telephone must be in Tone Dial DTMF mode to adjust the levels To Increase Audio Level Increase the audio level in steps by pressing F 8 also known as Up Continue to press 8 until the desired...

Страница 18: ...elay incorrectly you ll hear three short beeps followed by the programming tone That is your cue to re try the steps above If correct you ll hear the programming tone again Hang up Your Phonecell is r...

Страница 19: ...below How To Set the In Call DTMF Signaling Option Pick up the handset and listen for dial tone Then enter the User Programming mode by pressing 0 1 2 3 4 5 6 7 8 The dial tone should change to a ste...

Страница 20: ...ture or Ventilation Problems Visually inspect your Phonecell unit s enclosure Moisture can damage the equip ment Ventilation is also very important If there are moisture or ventilation problems move y...

Страница 21: ...mission FCC proposed the adoption of this updated Standard The design of your Telular Phonecell SX3 FWT complies with this updated Standard Of course if you want to limit RF exposure even further than...

Страница 22: ...ergy However RF energy from cellular devices may affect inadequately shielded electronic equip ment RF energy may affect improperly installed or inadequately shielded electronic operating and entertai...

Страница 23: ...propane or butane must comply with the National Fire Protection Standard FPA 58 For a copy of this standard contact the National Fire Protection Association One Batterymarch Park Quincy MA 02269 Attn...

Страница 24: ...ode Use the following access code to enter the Programming mode Press 0 1 2 3 4 4 3 2 1 The access code is 8 digits If the access code is not 8 digits or does not match the stored access code the Tech...

Страница 25: ...xisting stored parameter will remain The factory default setting is 1 How to Set the Roam Option Use the following key sequence to set the Roam option Press 6 Roam option The brackets represent the 1...

Страница 26: ...g factory default setting is 1 How to Initiate a Ring Back Request Use the following key sequence to initiate an immediate Ring Back Press 13 There is no Ring Back value to be entered the command acti...

Страница 27: ...Part No 56016602 1999 Telular Corporation all rights reserved Printed in the USA...

Отзывы: