background image

 

Quick Manual 

v1.0 

ADVANCED 3G TERMINAL WITH 

FLEXIBLE INPUTS 

CONFIGURATION 

FMU130 

Содержание FMU130

Страница 1: ...Quick Manual v1 0 ADVANCED 3G TERMINAL WITH FLEXIBLE INPUTS CONFIGURATION FMU130 ...

Страница 2: ...ct the battery 6 PC Connection Windows 7 How to install USB drivers Windows 7 Configuration Windows 7 Quick SMS configuration 9 Mounting recommendations 10 LED indications 11 Characteristics 11 Basic characteristics 11 Electrical characteristics 13 Safety information 14 Certification and Approvals 15 Warranty 16 Warranty Disclaimer 16 ...

Страница 3: ...3 FMU130 Wiki Know your device Figure 1 FMU130 device view ...

Страница 4: ...nnel 3 4 DIN2 N AIN1 Analog input channel 1 Input range 0 30 V DC Digital input channel 2 5 DIN 1 Digital input channel 1 6 INPUT 6 TX EXT LVCAN TX 7 GND Ground pin 10 30 V DC 8 DOUT 1 Digital output channel 1 Open collector output Max 3 3 A DC 9 DOUT 2 Digital output channel 2 Open collector output Max 3 3 A DC 10 1WIRE POWER 3 8 V output for 1 Wire devices 11 1WIRE DATA Data for 1 Wire devices 1...

Страница 5: ...5 FMU130 Wiki Figure 3 FMU130 Wiring scheme Wiring scheme 1 Automotive relay 1 ...

Страница 6: ...Wiki how to enter it later in Teltonika Configurator Make sure that Micro SIM card cut off corner is pointing forward to slot 3 Connect battery as shown to device Position the battery in place where it does not obstruct other components 4 After configuration see PC Connection Windows attach device cover back Figure 4 Cover removal Figure 5 Micro SIM card insert Figure 6 Battery connection Figure 7...

Страница 7: ...ver installation window 4 In the following window click Install button Setup will continue installing the driver and eventually the confirmation window will appear Click Finish to complete the setup Configuration Windows At first FMU130 device will have default factory settings set These settings should be changed according to the user s needs Main configuration can be performed via Teltonika Conf...

Страница 8: ...ty 1 Load from device loads configuration from device 2 Save to device saves configuration to device 3 Load from file loads configuration from file 4 Save to file saves configuration to file 5 Update firmware updates firmware on device 6 Read records reads records from the device 7 Reboot device restarts device 8 Reset configuration sets device configuration to default Most important configurator ...

Страница 9: ...e detected by accelerometer Ignition will be detected by vehicle power voltage between 13 2 30 V Device makes a record On Moving if one of these events happen 300 seconds passes Vehicle turns 10 degrees Vehicle drives 100 meters Speed difference between last coordinate and current position is greater than 10 km h Device makes a record On Stop if 1 hour passes while vehicle is stationary and igniti...

Страница 10: ...g on the car model this may happen in 5 to 30 minutes period When the module is connected measure the voltage again to make sure it did not decrease It is recommended to connect to the main power cable in the fuse box 3 A 125 V external fuse shall be used Connecting ignition wire Be sure to check if it is a real ignition wire i e power does not disappear after starting the engine Check if this is ...

Страница 11: ...ty Off Device is not working or Device is in boot mode Characteristics Basic characteristics Table 5 Basic characteristics Module Name Quectel UC15 E UC15 A UC15 T or Quectel UG96 TM2500 Technology 3G UMTS HSPA 2G GSM GPRS GNSS BLUETOOTH GNSS GNSS GPS GLONASS GALILEO BEIDOU SBAS QZSS DGPS AGPS Receiver 33 channel Tracking sensitivity 165 dBM Accuracy 3 m Hot start 1 s Warm start 25 s Cold start 35...

Страница 12: ... 6 mm L x W x H Weight 55 g Operatingenvironment Operating temperature without battery 40 C to 85 C Storage temperature without battery 40 C to 85 C Operating humidity 5 to 95 non condensing Ingress Protection Rating IP41 Battery charge temperature 0 C to 45 C Battery discharge temperature 20 C to 60 C Battery storage temperature 20 C to 45 C for 1 month 20 C to 35 C for 6 months Features Sensors ...

Страница 13: ... V Input Voltage threshold DIN1 7 5 V Analog Input Input voltage Recommended Operating Conditions Range 1 0 10 V Input resistance Range 1 150 kΩ Measurement error on 12V Range 1 0 9 Additional error on 12 V Range 1 108 mV Measurement error on 30 V Range 1 0 33 Additional error on 30 V Range 1 88 mV Input Voltage Recommended Operating Conditions Range 2 0 30 V Input resistance Range 2 150 kΩ Measur...

Страница 14: ...cess which is inaccessible to the operator All related devices must meet the requirements of EN 60950 1 standard The device FMU130 is not designed as a navigational device for boats Do not disassemble the device If the device is damaged the power supply cables are not isolated or the isolation is damaged DO NOT touch the device before unplugging the power supply All wireless data transferring devi...

Страница 15: ... is necessary to read the User s Manual before your start using the device Full User s Manual version can be found in our Wiki This sign on the package means that all used electronic and electric equipment should not be mixed with general household waste Hereby Teltonika declare under our sole responsibility that the above described product is in conformity with the relevant Community harmonizatio...

Страница 16: ...quivalent repaired product fulfilling the same functionality TELTONIKA can also repair products that are out of warranty at an agreed cost Warranty Disclaimer TELTONIKA PRODUCTS ARE INTENDED TO BE USED BY PERSONS WITH TRAINING AND EXPERIENCE ANY OTHER USE RENDERS THE LIMITED WARRANTIES EXPRESSED HEREIN AND ALL IMPLIED WARRANTIES NULL AND VOID AND SAME ARE HEREBY EXCLUDED ALSO EXCLUDED FROM THIS LI...

Отзывы: