![Teltonika FMM13A Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/teltonika/fmm13a/fmm13a_quick-manual_1084789017.webp)
Quick Manual v1.5 // FMM13A
17
Telematics
Characteristic description
Value
Supply voltage
Min.
Typ.
Max.
Unit
Input Voltage
(Recommended
Operating Conditions),
Range 2
0
+30
V
Input resistance,
Range 2
150
kΩ
Measurement error on
12 V, Range 2
0.9
%
Additional error on 12
V, Range 2
108
mV
Measurement error on
30 V, Range 2
0.33
%
Additional error on 30
V, Range 2
88
mV
Output supply voltage 1-wire
Supply voltage
+4.5
+4.7
V
Output inner resistance
7
Ω
Output current (Uout
> 3.0 V)
30
mA
Short circuit current
(Uout = 0)
75
mA
Characteristic description
Value
Supply voltage
Min.
Typ.
Max.
Unit
Negative input
Input resistance
38.45
kΩ
Input voltage
(Recommended
Operating Conditions)
0
Supply
oltage
V
Input voltage threshold
0.5
V
Sink current
180
nA