![Teltonika FMB910 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/teltonika/fmb910/fmb910_quick-manual_1084777013.webp)
13
Table 5 Electrical characteristics
CHARACTERISTIC DESCRIPTION
VALUE
MIN. TYP. MAX.
UNIT
SUPPLY VOLTAGE
Supply Voltage (Recommended Operating
Conditions)
+6
+30
V
DIGITAL OUTPUT (OPEN DRAIN GRADE)
Drain current (Digital Output OFF)
120
µA
Drain current (Digital Output ON,
Recommended Operating Conditions)
0.6
A
DIGITAL INPUT
Input resistance (DIN1)
47
kΩ
Input voltage (Recommended Operating
Conditions)
0
Supply
voltage
V
Input Voltage threshold (DIN1)
3.9
V
ANALOG INPUT
Input voltage (Recommended Operating
Conditions)
0
+30
V
Input resistance
150
kΩ
Measurement error on 12V
3
%
Additional error on 12 V
360
mV
Measurement error on 30 V
3
%
Additional error on 30 V
900
mV
ABSOLUTE MAXIMUM RATINGS
Supply Voltage
-32
+32
V
Drain-Source clamp threshold voltage,
(I
drain
= 2 mA)
+36
V
Digital Input Voltage
-32
+32
V
Analog Input Voltage
-32
+32
V
Analog Input error margin can increase if temperature
varies.