background image

 

FMB204 | 

Wiki

 

PC Connection (Windows) 

1.

 

Power-up FMB204 with 

DC voltage (6 – 30 V)

 power supply 

using 

power cable

. LED’s should start blinking, see “

LED 

indications

”. 

2.

 

Connect device to computer using 

Micro-USB cable

 or 

Bluetooth

 connection: 

 

Using 

Micro-USB cable

 

 

You will need to install USB drivers, see “

How to install 

USB drivers (Windows)

 

 

Using 

Bluetooth

 

 

FMB204 Bluetooth is enabled by default. Turn on 

Bluetooth 

on your PC, then select 

Add Bluetooth or 

other device

 > 

Bluetooth

. Choose your device named – 

FMBxxx_last_7_imei_digits

”, without 

LE

 in the end.  

Enter default password 

5555

, press 

Connect 

and then 

select 

Done

.  

3.

 

You are now ready to use the device on your computer. 

How to install USB drivers 
(Windows) 

1.

 

Please download COM port drivers from 

here

 

2.

 

Extract and run 

TeltonikaCOMDriver.exe

.  

3.

 

Click 

Next

 in driver installation window.  

4.

 

In the following window click 

Install

 button.  

Setup will continue installing the driver and eventually the 
confirmation window will appear. Click 

Finish

 to complete the 

setup. 

Configuration (Windows) 

At first FMB204 device will have default factory settings set. These 
settings should be changed according to the user's needs. Main 
configuration can be performed via 

Teltonika

 

Configurator

 

software. Get the latest 

Configurator 

version from 

here

.

 

Configurator operates on 

Microsoft Windows OS

 and uses 

prerequisite 

MS

 

.NET Framework

. Make sure you have the correct 

version installed.

 

Table 2 MS .NET requirements 

MS .NET requirements

 

Operating 
system 

MS .NET Framework 
version 

Version 

Links 

Windows Vista 
Windows 7 
Windows 8.1 
Windows 10 

MS .NET Framework 
4.6.2 

32 and 64 bit 

www.microsoft.com

 

Downloaded 

Configurator

 will be in compressed archive. Extract it 

and launch 

Configurator.exe

. After launch software language can 

be changed by clicking

         

 in the right bottom corner (

Figure 10 

Language selection

). 

Содержание FMB204

Страница 1: ...Quick Manual v1 0 Advanced waterproof tracker FMB204...

Страница 2: ...t the battery 6 PC Connection Windows 7 How to install USB drivers Windows 7 Configuration Windows 7 Quick SMS configuration 9 Mounting recommendations 10 LED indications 11 Characteristics 11 Basic c...

Страница 3: ...3 FMB204 Wiki Know your device Figure 1 FMB204 device view...

Страница 4: ...1 DIN 2 Digital input channel 2 DIN 3 Digital input channel 3 AIN 1 Analog input channel 1 Input range 0 30 V DC DOUT 1 Digital output channel 1 Open collector output Max 3 3 A DC DOUT 2 Digital outp...

Страница 5: ...5 FMB204 Wiki Figure 3 FMB204 Wiring scheme Wiring scheme 1 Automotive relay 1...

Страница 6: ...r Wiki how to enter it later in Teltonika Configurator Make sure that Micro SIM card cut off corner is pointing forward to slot 4 Connect battery as shown to device 5 After configuration see PC Connec...

Страница 7: ...tallation window 4 In the following window click Install button Setup will continue installing the driver and eventually the confirmation window will appear Click Finish to complete the setup Configur...

Страница 8: ...1 Load from device loads configuration from device 2 Save to device saves configuration to device 3 Load from file loads configuration from file 4 Save to file saves configuration to file 5 Update fi...

Страница 9: ...detected by accelerometer Ignition will be detected by vehicle power voltage between 13 2 30 V Device makes a record On Moving if one of these events happen 300 seconds passes Vehicle turns 10 degree...

Страница 10: ...e in the fuse box 3 A 125 V external fuse shall be used Connecting ignition wire Be sure to check if it is a real ignition wire i e power does not disappear after starting the engine Check if this is...

Страница 11: ...mode Blinking every two seconds Sleep mode Blinking fast for a short time Modem activity Off Device is not working or Device is in boot mode Characteristics Basic characteristics Table 5 Basic charact...

Страница 12: ...t 205 g Operatingenvironment Operating temperature without battery 40 C to 85 C Storage temperature without battery 40 C to 85 C Operating humidity 5 to 95 non condensing Ingress Protection Rating IP6...

Страница 13: ...put ON 120 m DigitalInput Input resistance DIN1 59 9 k Input resistance DIN2 DIN3 67 5 k Input voltage Recommended Operating Conditions 0 60 V Input Voltage threshold DIN1 7 5 7 7 8 V Input Voltage th...

Страница 14: ...tor All related devices must meet the requirements of EN 60950 1 standard The device FMB204 is not designed as a navigational device for boats Do not disassemble the device If the device is damaged th...

Страница 15: ...is necessary to read the User s Manual before your start using the device Full User s Manual version can be found in our Wiki This sign on the package means that all used electronic and electric equip...

Страница 16: ...product Replaced with an equivalent repaired product fulfilling the same functionality TELTONIKA can also repair products that are out of warranty at an agreed cost Warranty Disclaimer TELTONIKA PRODU...