42
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on) parameters
Value type
-2147483648
2147483648
0
IO#1 property parameter (ID=300)
IO#1 priority (ID=301)
IO#1 High level (ID=302)
IO#1 logic operand (ID=304)
IO#1 averaging length (ID=305)
S32
IO#1 logic operand (ID=304)
Parameter defines when event is sent: 0: on range exit, 1: on range entrance, 2: both, 3:
monitoring.
Minimal
value
Maximum
value
Recommended
value
Goes with (depends on) parameters
Value type
0
3
3
IO#1 property parameter (ID=300)
IO#1 priority (ID=301)
IO#1 High level (ID=302)
IO#1 Low level (ID=303)
IO#1 averaging length (ID=305)
S8
IO#1 averaging length (ID=305)
Parameter defines IO property sample length to average. If no averaging needed default value
is 1.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on) parameters
Value type
0
2147483648
1
IO#1 property parameter (ID=300)
IO#1 priority (ID=301)
IO#1 High level (ID=302)
IO#1 Low level (ID=303)
IO#1 logic operand (ID=304)
S32
Other IO property elements are configuring in same logic. All IO elements parameter list is
below.
IO Element Number
IO element parameters
IO#1 – Digital input 1
300 – 305
IO#2 – Digital input 2
310 – 315
IO#3 – Digital output 1
320 – 325
IO#4 – Digital output 2
330 – 335
IO#5 – PDOP
340 – 345
IO#6 – HDOP
350 – 355
IO#7 – Power voltage
360 – 365
IO#8 – GPS power
370 – 375
IO#9 – PCB temperature
380 – 385
IO#10 – Movement sensor
390 – 395
IO#11 – Odometer
400 – 405
IO#12 – n/a
410 – 415
IO#13 – n/a
420 – 425
IO#14 – n/a
430 – 435
Содержание FM2200