10
3.4.3 FMA1YX/FM11YX IO Elements
For FMA1YX/FM11YX devices first ID number is always “
2
”, second and third ID numbers refers
to specific CAN-CONTROL IO element (
). And the last ID number refers to sections –
Property
;
Generation Type
;
Low level
,
High level
and
Averaging Constant
Here’s example:
ID 2013 – configures Accelerator Pedal position parameter “High Level”
Table 3 CAN-CONTROL IO elements SMS configuration Ids range
CAN-CONTROL IO Element
Parameter Ids range
Speed
2000-2004
Accelerator pedal position
2010-2014
Total fuel used
2020-2023
Fuel level (liters)
2030-2034
Engine RPM
2040-2044
Total mileage
2050-2053
Fuel level (percent)
2060-2064
Program number
2070-2073
Module ID
2080-2083
Total Mileage (counted)
2110-2113
Fuel Consumed (counted)
2120-2123
Engine Temperature
2170-2174
Control State Flags
2230-2233
Security State Flags
2320-2323
Table 4 CAN-CONTROL IO parameters configuration
Parameter ID
Parameter name Available values
2xx0
Priority
0 – IO element disabled
1 – Low priority
2 – High priority
3 – Panic priority
2xx1
Generation type
0 – Event on exit
1 – Event on entrance
2 – Event on both
3– Monitoring
4 – Hysteresis
5 – On change
2xx2
Low level
2xx3
High Level
2xx4
Averaging
Constant
From 0 to 2
32
Содержание CAN-CONTROL