S8
Pause for Comma in Dial String
This command contains the number of the seconds the T-311 pauses when it receives a comma in a
dial sequence. Multiple commas can also be entered in the dial string for longer delays.
Valid range:
0-255
Units:
seconds
Default:
2
S10
Call Disconnect Timeout
This command sets the amount of time the unit must detect no activity on the line before disconnect-
ing the call. A value of 0 disables the function.
Valid range:
0-255
Units:
seconds
Default:
0
S11
DTMF Dialing Rate
This command contains the duration of DTMF tones. The spacing between the tones is always the
same value. The longer the duration, the slower the dialing.
Valid range:
50-255
Units:
milliseconds
Default:
70
S13
Data Word Format
This command stores the parity information for T-311 data. Changes to this register are made by re-
mapping the bits, as described in Appendix C. Also see the appendix for information on reading the
contents of this register. The default data word format is an 8-bit data word, with parity set to “off” (ig-
nore parity). The status of bit 4 (Response to DTR) affects the T-311’s recognition of other bits as
follows:
When bit 4 is set to off and parity is on, bit 5 is ignored.
When bit 4 is off and parity is off, bit 3 is ignored.
When bit 5 is set to “on”, bits 2 and 3 are ignored.
Position
Value
Function
BIT 0
—
Not used
BIT 1
0
Not used
BIT 2
0
Parity off
(default)
BIT 2
1
Parity on
BIT 3
0
Odd parity
BIT 3
1
Even parity
(default)
BIT 4
0
7 data bits
(default)
BIT 4
1
8 data bits
BIT 5
0
BIT 8 = 0 (SPACE PARITY)
(default)
BIT 5
1
BIT 8 = 1 (MARK PARITY)
BIT 6
—
Not used
BIT 7
—
Not used
To display the current contents of this register, issue the command ATS13?<CR>. The default re-
sponse is 8. To turn on even parity, send: ATS13=12<CR>.
T-311
Page 34
Содержание T-311
Страница 1: ...Telephone Access Unit T 311 Product Manual 40 400 00045 Rev B ...
Страница 8: ...This page intentionally left blank T 311 Page vi ...
Страница 10: ...T 311 Page 2 Figure 1 T 311 Telephone Access Unit ...
Страница 17: ...Reference Manual Chapter 4 Dialing Instructions 40 400 00045 Rev B Page 9 Figure 3 System Connections ...
Страница 20: ...T 311 Page 12 Figure 5 Universal Mounting Bracket Optional Figure 6 Universal Mounting Shelf Optional ...
Страница 58: ...T 311 Page 50 Figure 7 T 311 Block Diagram ...