QUICK-START INSTALLATION GUIDE

TELOS INFINITY LINK 

Gateway IP Codec

INTRODUCTION 

Telos Infinity Link enables Infinity systems in remote locations to connect to one another using an 

embedded, versatile, speech-optimized OPUS codec over the public Internet or private infrastructure.

This Telos Infinity Link Gateway is a dedicated, rack-mounted, hardware platform with dual redundant 

internal power supplies and dual Gigabit Ethernet ports. It can be configured with either eight or sixteen 

bi-directional mono codecs, making it an ideal choice for higher density applications. 

Infinity Link is also available as licensed software in Infinity Intercom Master Panels, Infinity Expansion 

Panels, and Infinity Desktop Panels (4 or 8 codecs) and Infinity Beltpacks (2 codecs). 

Содержание Infinity Link

Страница 1: ...This Telos Infinity Link Gateway is a dedicated rack mounted hardware platform with dual redundant internal power supplies and dual Gigabit Ethernet ports It can be configured with either eight or si...

Страница 2: ...Sync LED D When the Link Gateway locks to its reference clock this LED will be solid green A blinking green LED indicates the unit is drifting from its reference to some degree with more rapid blinki...

Страница 3: ...t should be connected to the network on which you intend to stream This network should have internet access and must be connected to a Gigabit 1000Base T port on your router Power Supply Inlets I J Tw...

Страница 4: ...SU failure the loss of mains supply voltage is a bigger concern Accordingly each supply should be fed from a different circuit equipped with adequate surge protection and fitted with an uninterruptabl...

Страница 5: ...nfinity Link Gateway is set up with DHCP enabled so that it will receive an IP address automatically when connected to a network with a DHCP server DHCP can be disabled and a static address entered if...

Страница 6: ...e the cursor to the first character of the IP address 4 The Up and Down arrows change the value of the selected character 5 The Left and Right arrows move the cursor back and forth between characters...

Страница 7: ...e value based on the unit s MAC address We recommend you leave this value unchanged and use the Label field to create an easily recognized name for the Link Gateway If you do elect to change the ID it...

Страница 8: ...ny changes to the IP settings click Apply to apply and save any changes Refreshing the browser page to rescan the network may be necessary after doing so When the Slave Only mode is On Infinity Link G...

Страница 9: ...Link Screen Each of the available OPUS codecs a total of eight or sixteen depending upon licensing is configured in this menu Figure 8 Link screen QUICK START INSTALLATION GUIDE...

Страница 10: ...ad a log file if instructed to do so by customer support The current user license is displayed on this screen along with a field into which additional licenses may be entered when adding features or c...

Страница 11: ...abel Once the Input Label is set open Dashboard Basic or Advanced Navigate to the Output pane and type the Input label into the search box Drag and drop the output into the Virtual Port or Group you w...

Страница 12: ...icast Address into the Output Channel Address field Add a label to describe the audio source you are receiving in the Output Label field Below is an example of a fully filled in Audio Configuration se...

Страница 13: ...to peer the Infinity Link Select an appropriate bitrate and type from the Codec Profile dropdown menu Each codec represents a single audio channel so choosing 2 channel stereo from the Channel menu a...

Страница 14: ...nel number while non Livewire AES67 devices will display the multicast address Avoiding duplicate addresses and the resulting conflicts is critical and so knowing how to convert a Livewire channel num...

Страница 15: ...t number can be used but we recommend a non standard port starting at 21000 Some Notes on Port Forwarding The concept of port forwarding also known as port mapping is often misunderstood but critical...

Страница 16: ...4001 UDP to the local IP address of the Secondary port on our Link Gateway which is 10 0 0 102 Now when the Link Gateway unit on the far end configures its Peer Device Information as PublicIPAddress 2...

Страница 17: ...THIN AN INFINITY SYSTEM Below is an example of how to Infinity Link Gateways might connect a studio together with a remote location Figure 15 Example with Infinity Link Gateways at both locations QUIC...

Страница 18: ...Figure 16 Example with Infinity Link Gateway with Link Gateway studio location only QUICK START INSTALLATION GUIDE...

Страница 19: ...This Page Intentionally Blank QUICK START INSTALLATION GUIDE...