Installation
AERO.100 is a 1RU product intended to be permanently installed in a standard 19 ½” equipment rack and
secured with four standard rack screws. It is fan cooled with air intakes and exhausts located on the side
of the unit just behind the front panel, but whenever possible, it is recommended to leave 1RU of empty
space above and below the unit.
Power
There is no on/off switch. AERO.100 will power up when power is applied to either power supply. To
power down, simply remove power from both supplies.
Each of the supplied IEC power cords should be connected to different mains power sources. Remember
that while redundant supplies do protect against the unit losing power in the event of a PSU failure, the
loss of mains supply voltage is a bigger concern. Accordingly, each supply should be fed from a different
circuit equipped with adequate surge protection and fitted with an uninterruptable power supply (UPS).
Note:
AERO.100 is a “headless” product and as such has no local front panel controls. The display is
used only to show the current software version, host name, and IP address of the unit. Setup
and configuration relies upon the use of NfRemote client software as explained below.
Connecting Inputs and Outputs
Connect inputs and outputs as required for your particular installation. AERO.100 can access any of
the eight audio pairs carried on an incoming HD- or SD-SDI stream and provide de-embedding and pair
shuffling at its input. Audio can also be received using the AES-3 inputs. Detailed instructions on audio
routing are provided in the full AERO.100 user manual.
INSTALLATION AND INITIAL SETUP