background image

 

 

PB007326 Rev E
Page 22 of 24

 

Appendix D:  TSUR-400 Menu Flow Chart 

 
 Pwr-Up Splash 

                               

 

 

 

 

 

 

      

Menu Level  

 
 
                                                                                                                                                                     

 

Message Screen

Split on

 

 
 

 UP 

      

Auto  

 

 after 3 sec  

 

 

 

 

 

Diag ON

 

  

 

 

 Main Screen

    

     

 

 

   Split off   

 

 

 

 

   FN Returns  

 

   

 

 

 

 

 

 

 

   

t

o Setup Menu 

 

 

 

 

 

SG 

 

 

 

 

 

    

 

 

 

 

 

 

 
 

 

 

    

 

 
 
 

             FN 

 

 

         

                 

 

 

 

     

Setup (Menu Level 2)

 

    

 

 

 

           Submenu   

 

 

 

   

Menu Level 1 

     

           FN          FN 

 

 

 

 

 

 

 

 

 

 

 

      

FN for all 

 

 

 

 

 

 

 

 

 

       Selects

 

 
 

 

 

          

 

 

 

 

 
 

 

       

 

 

 

        FN 

 

 

 

 

 

 

 

          

FN 

 

 

  

      

FN        

 

 

     

 

 
 
 
 
 
 
 
 
 
 
 
 

 

    

 

 
 

   Telonics Inc 

2001.11.10 

15:45   #m99 

all split dg 

TSUR-400 

Ser# xxxxxxx 

Ver 1.00 

2002.06.12

 

 

15:46:22 XXX 

? ID XXXXXX

401.670 MHz   

01 xxxxxxxxa 

 

15:46:22 XXX 

? ID XXXXXX

401.670 ddd 

Ddd ddd ddd a 

Exit 

Volume

  

08 

     Diag  ON 

Split ON 

Update ON 

Beep     ON 
Edit ID Tab 

Audio    ON 

ID Filter ON 

RF Power ON 

 Msg Export 

Msg Delete  

Setup 

Volume     8 

UP Increase 

DN Decrease 

FN to Set 

99  Messages 

xx Selected  

UP/ DN Select 

FN to Begin

 

Msg Delete 

None 

UP/DN Select 

FN Accepts

  

Exit 

28Bit ID Tbl 

Edit ID Filt 

Split setup 

Beep Tone 

Lite On Time 

Set Time 

Set Date 

Sw Closure 

Squelch 

Fact Default 

RF Pwr Dsply 

PC Connect 

Bit Splt 001 

00 bits long 

UP/DN Select 

FN to Set 

Set Time 

xx:xx 

UP/DN Select 

FN Advances

 

Set Date  

yyyy.mm.dd  

UP/DN Select 

FN Advances

 

Sw Closure 

xx.x Seconds 

UP/DN Select 

FN to Set

 

Squelch 

x  

UP/DN Select 

      FN to Set

 

Fact Default 

No 

UP/DN Toggle 

FN to Set

 

RF Pwr Dsply 

 dbn 

UP/DN Toggle 

FN  to Set

 

PC Connect 

 In process 

 

FN  to exit

 

Beep Tone 

Tone 9 

UP/DN Select 

       FN to Set 

Lite On Time 

15 Seconds 

UP/DN Select 

FN to Set 

 

   FF  FE 2F 
   OF B3 AD 

Xx xx xx xx 
Xx xx xx xx 

 

02 xxxxxxxx 
03 xxxxxxxx 
04 xxxxxxxx    

05 xxxxxxxxb 

 

Ddd ddd ddd 
Ddd ddd ddd 
Ddd ddd ddd 

Ddd ddd ddd b 

 

Carrierxxxms  

401.6704MHz 

   xx.xxxxxx W 
 ?Data Grps x 

ID Filter 

Exit 

UP/DN Select 

FN to Set 

28Bit ID Tbl 

Exit 

UP/DN Select 

FN to Set 

Содержание TSUR-400

Страница 1: ...E MAIL info telonics com www telonics com TSUR 400 RECEIVER MONITOR OPERATION and PROGRAMMING MANUAL PB007326 Rev E 2012 08 07 Copyright Notice Copyright 2012 Telonics Inc All Rights Reserved No part...

Страница 2: ...xport 9 J Msg Delete 10 K Setup 10 Setup Menu Level 2 Screen 11 A 28bit Id Tbl 11 B Edit Id Fltr 12 C Split Setup 13 D Beep Tone 13 E Lite On Time 13 F Set Time 14 G Set Date 14 H Sw Closure 14 I Sque...

Страница 3: ...d toggle menu items On or Off The FN key is also used to exit from the Message screen or to enter the Menu system DN P1 Key The DN key is a scroll down key used for scroll down menu options The DN key...

Страница 4: ...een which displays the current date and time number of stored messages selected group or all ID codes data bytes split or decimal and diagnostics dg on or off Changes or modifications to these paramet...

Страница 5: ...automatically whenever a new message is received or manually by pressing the DN key at the Main screen The information displayed is the date and time of the most recent message current message number...

Страница 6: ...t a time with the most recent message displayed first The scroll speed increases when the UP or Dn key is depressed for more than 2 seconds When the last message is scrolled a message indicating end o...

Страница 7: ...haracter on white background with a black block Pressing the FN key allows the selected function to be modified Exiting back to the Main Screen is accomplished by selecting EXIT using the UP or DN key...

Страница 8: ...RF Pwr mode before directly connecting it to a transmitter You may damage the TSUR 400 if you directly connect a transmitter while it is in receive mode 4 Comparison of the number of data groups the...

Страница 9: ...is Off All is displayed on the left side of the bottom line of the display When Id Fltr is On the receiver will display information only when a new message is received for an ID that is in the GRouP o...

Страница 10: ...sed to begin the process Press the FN key to return to the Main Screen When exporting messages the following parameters define how the information is sent RS 232 9600 Baud 8 Bits No Parity 1 Stop Bit...

Страница 11: ...enu screen Line 1 Exit Line 2 28bit Id Tbl Line 3 Edit Id Fltr Line 4 Split setup Beep Tone Lite On Time Set Time Set Date SW Closure Squelch Fact Default RF Pwr Dsply PC connect A 28bit Id Tbl The 28...

Страница 12: ...coming messages or just selected messages maximum of 9 Edit Id Fltr is selected by highlighting the feature and pressing the FN key The following display appears Choices are Exit Erase All or Edit or...

Страница 13: ...rated when a beep occurs When this feature is selected and the FN key pressed the following appears Choices are 1 to 9 with each number corresponding to a different tone Each time a new number is sele...

Страница 14: ...ction mm Selection between 01 and 12 is accomplished using the UP DN keys When the correct number is displayed the FN key advances the highlight to the day selection dd Selection between 01 and 31 is...

Страница 15: ...t J Fact Default Warning Implementing this function will erase ID codes the user may have programmed into the TSUR 400 This feature is used to return the unit to the factory defaults that were origina...

Страница 16: ...e reading programming of user parameters and reading clearing of stored messages Note When the receiver is in this mode the RF section is disabled precluding reception of messages When this feature is...

Страница 17: ...fff fff ddd ddd eee CR where LF ASCII Line Feed code 0x0A y year decimal 2001 2002 etc M month decimal 1 12 d day of month decimal 1 31 h hour decimal 0 23 m minute decimal 0 59 s second decimal 0 59...

Страница 18: ...0 FF eeee error messages Alpha letters CR ASCII Carriage Return code 0x0D d Diagnostics Mode with Split Bits COMMA delimited field information as follows LF yyyy MM dd hh mm ss iiiiii fff fff CCC pp p...

Страница 19: ...l message received was longer or shorter than the message length indicated by the three bit message length indicator which was transmitted b Length Parity Error Indicates that the three bit message le...

Страница 20: ...External Power 9 to 48 Vdc with power adapter pack Power Measurement 0 01 to 1 watt 0 to 30 dBm For measuring power levels exceeding 1 0 watt 30 dBm appropriate external attenuators are required NOTE...

Страница 21: ...ORANGE and will remain ORANGE for two to three minutes until the charger brings the battery to the correct voltage level It will then turn RED to indicate that the charger is in the rapid charge state...

Страница 22: ...gin Msg Delete None UP DN Select FN Accepts Exit 28Bit ID Tbl Edit ID Filt Split setup Beep Tone Lite On Time Set Time Set Date Sw Closure Squelch Fact Default RF Pwr Dsply PC Connect Bit Splt 001 00...

Страница 23: ...orks with Telonics Data Converter and terminal programs Using Telonics Data Converter TDC TDC is available for download on the Telonics website and will save TSUR 400 messages to a text file free of c...

Страница 24: ...n STOP and data collection to the text file will be terminated TSUR 400 WARRANTY Telonics warrants the TSUR 400 to be free from defects in material and workmanship for 90 days from the date acquired T...

Отзывы: