8
The EMR KB/KU – AP/OF lock has two operational modes (functions):
Emergency Lockdown – Mode 0, and Relock – Mode 1. The factory default
setting is Relock – Mode 1.
Emergency Lockdown – Mode 0
In Emergency Lockdown – Mode 0, the lock temporarily disables all user codes except the
master code, and immediately locks the door. A master code or optional remote release
temporarily unlocks door to allow entry, then relocks.
1. Enter master code, followed by #.
2. Press zero (0).
3. Press *.
Key Stroke Example
Emergency
Lockdown –
Mode 0
1. Key in master code.
2. Press #.
3. Press zero (0).
4. Press *.
Relock – Mode 1
In Relock – Mode 1, the lock will unlock for 4 seconds, then relock. This mode is used when
you want the lock to remain secure at all times. Setting the device to Relock – Mode 1
immediately secures the door.
1. Enter master code, followed by #.
2. Press 1.
3. Press *.
OF Lock: Relock – Mode 1: Rotating thumbturn on inside puts lock into extended
Passage Mode (unlocks) until thumbturn is returned to home position securing the lock
.
Key Stroke Example
Relock –
Mode 1
1. Key in master code.
2. Press #.
3. Press 1.
4. Press *.